aIr condItIonIng unIt maSter Stateroom
The Air Conditioning Unit Master Stateroom breaker controls the flow of electricity to the air conditioning unit that cools the aft state-
room and port head . To supply power to the unit, switch the A/C System Water Pump breaker ON, before switching the Air Condition-
ing Unit Master Stateroom breaker ON .
CauTiON
DO nOt SWitch thE AiR cOnDitiOning Unit mAStER StAtEROOm bREAkER On UntiL AFtER thE SEAcOck SUp-
pLying thE AiR cOnDitiOning SyStEm With SEAWAtER hAS bEEn OpEnED. REFER tO SEctiOn 4 -
air Condition-
ing systeM
FOR mORE inFORmAtiOn.
port Salon ac unIt
The PORT Salon AC Unit breaker controls the flow of electricity to the air conditioning unit that cools the salon . To supply power to
the unit, switch the A/C System Water Pump breaker ON, before switching the Air Conditioning Unit Salon breaker ON .
CauTiON
DO nOt SWitch thE AiR cOnDitiOning Unit SALOn bREAkER On UntiL AFtER thE SEAcOck SUppLying thE AiR
cOnDitiOning SyStEm With SEAWAtER hAS bEEn OpEnED. REFER tO SEctiOn 4 -
air Conditioning systeM
FOR
mORE inFORmAtiOn.
Stbd Salon ac unIt
The STBD Salon AC Unit breaker controls the flow of electricity to the air conditioning unit that cools the salon . To supply power to the
unit, switch the A/C System Water Pump breaker ON, before switching the Air Conditioning Unit Salon breaker ON .
CauTiON
DO nOt SWitch thE AiR cOnDitiOning Unit SALOn bREAkER On UntiL AFtER thE SEAcOck SUppLying thE AiR
cOnDitiOning SyStEm With SEAWAtER hAS bEEn OpEnED. REFER tO SEctiOn 4 -
air Conditioning systeM
FOR
mORE inFORmAtiOn.
VIp/thrd ac unIt
The VIP/Third AC Unit breaker controls the flow of electricity to the air conditioning unit that cools the VIP/Third Stateroom . To supply
power to the unit, switch the A/C System Water Pump breaker ON, before switching the Air Conditioning Unit Salon breaker ON .
CauTiON
DO nOt SWitch thE AiR cOnDitiOning Unit SALOn bREAkER On UntiL AFtER thE SEAcOck SUppLying thE AiR
cOnDitiOning SyStEm With SEAWAtER hAS bEEn OpEnED. REFER tO SEctiOn 4 -
air Conditioning systeM
FOR
mORE inFORmAtiOn.
ShORE 2 CIRCUIT BREAKERS
ac maIn breaker Salon panel
Switch ON the AC Main Breaker Salon Panel
breaker to supply power to the Salon AC Distribution Panel .
central Vacuum
The Central Vacuum breaker controls the flow of electricity to the optional central vacuum system . Switch the Central Vacuum breaker
AC E
lECtriCAl
S
yStEm
AC E
lECtriCAl
S
yStEm
Содержание 500 Sport Bridge
Страница 1: ...HIN MQYE5041K213 500 Sport Bridge Owner s Manual 2013 Version 1...
Страница 2: ......
Страница 4: ......
Страница 7: ...Preface Preface 5027 E2 09 2011 i Lower Helm Components...
Страница 8: ...Preface Preface ii 5027 E5 09 2011 Bridge Helm Components...
Страница 28: ...Yachting Safety Yachting Safety 14 5027 E5 09 2011 page intentionally left blank...
Страница 41: ...5027 E5 09 2011 27 DC Electrical System DC Electrical System DC Control Center Schematic Engine ROom...
Страница 42: ...28 5027 E5 09 2011 DC Electrical System DC Electrical System PAGE INTENTIONALLY LEFT BLANK...
Страница 57: ...AC Electrical System AC Electrical System 43 5057 E5 09 2011...
Страница 58: ...50 Hz AC Electrical Schematic AC Electrical System AC Electrical System 5057 E5 09 2011 44...
Страница 59: ...60 Hz AC Electrical Schematic AC Electrical System AC Electrical System 45 5057 E5 09 2011...
Страница 60: ...page intentionally left blank AC Electrical System AC Electrical System 5057 E5 09 2011 46...
Страница 76: ...page intentionally left blank Internal Systems Internal Systems 62 5027 E5 09 2011...
Страница 86: ...Propulsion Propulsion 72 5027 E5 09 2011 PAGE INTENTIONALLY LEFT BLANK...
Страница 108: ...Maintenance Maintenance 94 5027 E5 09 2011 local Marquis dealer...
Страница 120: ...Warranty and Parts Warranty and Parts 106 5027 E5 09 2011 Thru Hull Fittings...
Страница 121: ...Warranty and Parts Warranty and Parts 5027 E5 09 2011 107 Bill of Materials...
Страница 122: ...Warranty and Parts Warranty and Parts 108 5027 E5 09 2011 Marquis Limited Warranty...