12-2
Preparing for Startup
ECODRIVE DKC01.1/DKC11.1 Drive Controllers
DOK-ECODRV-DKC01/11.1*-PRJ3-EN-P
To position the drive, a setpoint value must be input via the proper inter-
face (positioning, analog or stepper interface).
For test purposes a speed setpoint must be input via the analog inter-
face using a setpoint generator.
To do so, the EOCDRIVE must be switched to the main operating mode
"Speed control with an analog setpoint value!" when operating via the po-
sitioning or stepper interface.
The following figure illustrates a circuit proposal for a setpoint generator.
1
2
3
4
10k
V
13k
DC (-10...+10)V
+15 V
-15 V
E1
E2
IRED1
IRED2
1
2
3
4
24V
RF
AH/Start
0VM
drive enable
drive stop/start
AP0242.fh5
X3
X4
DKC
command value encoder
directional switch
command value
analog
command
value
input
Fig. 12-1: Circuit proposal setpoint ge nerator for connecting an analog interface
Setpoint generator