5-4
BZM auxiliary bleeder module
ECODRIVE DKC01.1/DKC11.1 Drive Controllers
DOK-ECODRV-DKC01/11.1*-PRJ3-EN-P
1. Continuous regenerative power
P
P
P
R D
BD, DK C
BD, B ZM
∑
∑
∑
≤
+
0 8
,
*
P
W
W
t
RD
+
ROT
POT
Z
=
∑
∑
* 1000
W
J
J
n
z
ROT
LAST
NUTZ
DEC
M
2
(
=
+
⋅
⋅
⋅
⋅
(
)
2
60
2
π
W
m
g h z
POT
LAST
AB
=
⋅ ⋅ ⋅
2. Peak regenerative power
P
P
P
RS
BM, DKC
BM, BZM
∑
≤
+
0 8
, *
P
RS
- > siehe Auswahldaten zu den Servoantrieben
3. Regenerative energy (a single braking in the E-stop position)
W
W
W
W
POT, MAX
ROT, MAX
MAX, DKC
MAX, BZM
+
*
*
∑
∑
∑
∑
≤
0 8
,
W
MAX, DKC
- > siehe Abb. Technische Daten DKC
W
MAX, BZM
- > siehe Abb. Technische Daten BZM
P
RD
:
continuous regenerative power of the mechanical system that
occurs in continuous operation in kW
P
BD, DKC
:
continuous regenerative power that the drive controller can
process in continuous operation in kW
P
RS
:
peak regenerative power in kW
W
ROT
:
rotary energy in Ws
W
POT
:
potential energy in Ws
W
ROT, MAX
:
max. occurring rotary energy in the E-stop position in Ws
W
POT, MAX
:
max. occurring potential energy in the E-stop in Ws
t
Z
:
cycle time in s
J
LAST
:
load torque in kgm²
J
M
:
motor inertia, in kgm²
m
LAST
:
load weight in kg
W
MAX, BZM
:
storable energy in BZM 01.1 in kWs
W
MAX, DKC
:
storable energy in the DKC in kWs
g: 9.81
ms²
h:
lowering dimension in m or number of bra king actions
n
NUTZ
:
motor speed used in min-1
z
AB
:
number of drops per cycle
z
DEC
:
number of braking actions per cycle
Fig. 5-3: Check the conditions for regenerative power and regenerative energy in
a DKC connected to a BZM via the DC bus
up to 6 DKCs + BZM