18000 SERIVCE/MAINTENANCE MANUAL
INTRODUCTION
1
Crane Modes
Standard mode is for all normal load-handling operations.
In Setup mode, the program allows limited operation of whip
line hoist, boom hoist, mast hoist, swing and travel.
In Setup Remote mode, program allows operation of items
on hand-held radio remote control.
In Luffing Jib mode, the program allows standard mode load
handling operations plus luffing jib operation.
In Tandem Drum mode, the program allows operation main
hoist 1 and 2 in tandem and other normal load-handling
operations.
In MAX-ER mode, the program allows operation of crane
and MAX-ER attachment as one system.
Electrical Power to Operator’s Cab
for the following procedure.
When key-operated engine switch is in STOP position,
voltage is available to operate dome light switch, and radio/
clock. When key-operated engine switch is placed in RUN
position, power is available to the following relays:
•
Engine control module relay (CU ECM)
•
Engine ether start relay (CU ES)
•
Cab power relay (CAB PWR)
•
CAN system ground relay (CAN GND)
•
Air conditioning system relay (A/C CLUTCH)
•
Engine starter solenoid relays (MS1/MS2)
•
CAN system power relay (CAN PWR)
When cab power relay is enabled, power is available to
operate crane controls (see Electrical Schematics in this
manual).
Pressure Senders and Speed Sensors
Pressure senders monitor drum system pressures, right/left
travel system pressure, swing right/left system pressure,
swing brake pressure (cranes without swing lock), accessory
system pressure, variable speed hydraulic cooler fan (tier 4
equipped), and high pressure accessory system pressure.
Each node controller receives input hydraulic pressure
information from each system pressure sender. Pressure
senders provide information on the required load holding
pressure for load drums, boom hoist drum, or luffing hoist
drum.
Drum speed sensors in motor rotors detect speed and
direction of drum movement. Node-1 controller receives this
information as two out-of-phase square wave voltages that
are converted to “counts”. The controller compares control
handle voltage with pump output to determine when to vary
pump stroke.
Содержание 18000
Страница 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 18000 ...
Страница 2: ...R e f e r e n c e O n l y ...
Страница 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Страница 210: ...R e f e r e n c e O n l y NOTES SKETCHES AND PHOTOGRAPHS ...
Страница 315: ...R e f e r e n c e O n l y ...
Страница 316: ...R e f e r e n c e O n l y ...