Reference
Only
18000 SERIVCE/MAINTENANCE MANUAL
HYDRAULIC SYSTEM
Manitowoc
Published 12-05-17, Control # 035-23
2-15
2
SAE Flare Connection
1.
Tighten nut finger tight until sealing surfaces touch.
2.
Mark a line (use felt pen or marker) on adapter and
extend it onto connector nut (
, View A).
3.
Using wrenches, tighten connector nut the number of
flats shown in (
, View B).
4.
Misalignment of marks will show how much nut has
been tightened, and best of all that it has been tightened.
Table 2-8 SAE 37
°
Flare Tightening
Table 2-9 SAE 37
°
Flare Leakage
Connector Nut
Size
inch across flats
Fitting Size
Adapter Flats
to Rotate
9/16
-04
2-1/2
5/8
-05
2-1/2
11/16
-06
2
7/8
-08
2
1
-10
1-1/2 – 2
1-1/4
-12
1
1-1/2
-16
3/4 – 1
2
-20
3/4 – 1
2-1/4
-24
1/2 – 3/4
FIGURE 2-13
Turn connector nut required
number of flats (
View B
S108
Adapter
Line
Connector
Nut
View A
Causes
Cures
Joint loose.
Tighten properly.
Sealing surfaces dirty.
Clean.
Sealing surfaces not smooth;
scratched or gouged.
Replace faulty parts.
Sealing surfaces cracked.
Replace faulty parts.
SAE 45° parts used with
SAE 37° parts.
Use only SAE 37° parts.
Содержание 18000
Страница 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 18000 ...
Страница 2: ...R e f e r e n c e O n l y ...
Страница 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Страница 210: ...R e f e r e n c e O n l y NOTES SKETCHES AND PHOTOGRAPHS ...
Страница 315: ...R e f e r e n c e O n l y ...
Страница 316: ...R e f e r e n c e O n l y ...