Reference
Only
Manitowoc
Published 12-05-17, Control # 035-23
3-11
18000 SERIVCE/MAINTENANCE MANUAL
ELECTRIC SYSTEM
3
NODE 3 - Drum 3 and Pressure Senders
Reference Electrical Schematic A06374 - Sheets 7, 19 and 20
.
Can ID. No.
Function
Type
Description
Test Voltage
Packet No.
WN10-A/WN04-A
24 Volts
From Node 0 to Node 4
24 Volts
WN10-C/WN04-C
CANH
Can High Wire Transmission
N/A
WN10-D/WN04-D
Ground
From Node 0 to Node 4
Ground
WN10-F/WN04-F
CANL
Can Low Wire Transmission
N/A
J3
Receptacle – Pressure Senders
33-B
DO-1
Super Charge Hydraulic Pressure (Prior to
S/N 18001082)
0 Volts Off; 24 Volts On
CAN33-1-1
33-C
Ground
Drum 2/5 Pressure Sender
Ground
33-D
DO-2
Drum 2/5 Pressure Sender
0 Volts Off; 24 Volts On
CAN33-1-2
33-E
Ground
Drum 1/3 Pressure Sender
Ground
33-F
DO-3
Drum 1/3 Pressure Sender
0 Volts Off; 24 Volts On
CAN33-1-4
33-G
Ground
Accessory System Pressure Sender
Ground
33-H
DO-4
Accessory System Pressure Sender
0 Volts Off; 24 Volts On
CAN33-1-8
33-J
Ground
Jumper to Node Select
Ground
33-L
NS-2
Node Select Jumper to Ground
0 Volts (With Jumper)
33-N
Ground
Right Track Pressure Sender
Ground
33-P
DO-6
Right Track Pressure Sender
0 Volts Off; 24 Volts On
CAN33-1-32
33-R
DO-5
Left Track Pressure Sender
0 Volts Off; 24 Volts On
CAN33-1-16
33-T
DI-3
Super Charge Hydraulic Pressure (Prior to
S/N 18001082)
0 Volts Off; 24 Volts On
CAN59-1-4
33-b
AI-2
Drum 2/5 Pressure Sender
1 Volt at 0 psi;
5 Volts at 7,500 psi
CAN4-4
1
33-c
AI-3
Drum 1/3 Pressure Sender
1 Volt at 0 psi;
5 Volts at 7,500 psi
CAN4-6
1
33-d
AI-4
Accessory System Pressure Sender
1 Volt at 0 psi;
5 Volts at 7,500 psi
CAN4-8
1
33-e
AI-5
Right Track Pressure Sender
1 Volt at 0 psi;
5 Volts at 7,500 psi
CAN5-2
1
33-f
AI-6
Left Track Pressure Sender
1 Volt at 0 psi;
5 Volts at 7,500 psi
CAN5-4
1
33-g
Ground
Left Track Pressure Sender
Ground
J4
Receptacle – Drum Pump Control
34-A
Ground
Drum 1/3 Pump Control – Raise
Ground
34-B
DO-11
Drum 1/3 Pump Control – Raise
See
for Values
CAN33-2-4
34-C
Ground
Drum 1/3 Pump Control – Lower
Ground
34-D
DO-12
Drum 1/3 Pump Control – Lower
See
for Values
CAN33-2-8
34-E
Ground
Drum 2/5 Pump Control – Raise
Ground
34-F
DO-13
Drum 2/5 Pump Control – Raise
See
for Values
CAN33-2-16
34-G
Ground
Drum 2/5 Pump Control – Lower
Ground
34-H
DO-14
Drum 2/5 Pump Control – Lower
See
for Values
CAN33-2-32
34-J
Ground
Drum 2 Pump Control – Raise
Ground
34-K
Ground
Drum 2 Pump Control – Lower
Ground
34-L
Ground
Drum 1/3 (opt.) Pump Control – Raise
Ground
34-M
DO-17
Drum 1/3 (opt.) Pump Control – Raise
See
for Values
CAN33-3-1
34-N
Ground
Drum 1/3 (opt.) Pump Control – Lower
Ground
Содержание 18000
Страница 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 18000 ...
Страница 2: ...R e f e r e n c e O n l y ...
Страница 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Страница 210: ...R e f e r e n c e O n l y NOTES SKETCHES AND PHOTOGRAPHS ...
Страница 315: ...R e f e r e n c e O n l y ...
Страница 316: ...R e f e r e n c e O n l y ...