Reference
Only
Manitowoc
Published 12-05-17, Control # 035-23
7-7
18000 SERIVCE/MAINTENANCE MANUAL
POWER TRAIN
7
stretch slightly, adjust themselves, and distribute the
sealing pressure evenly. To complete a tight seal, apply
pressure by hand at outer rim of filters, not the flexible
center. Avoid pushing center of urethane end cap. No
cover pressure is required to hold the seal. Again,
do
not
use service cover to push filter into place.
9.
Check connections for tight fit:
Make sure that all clamps, bolts, and connections in
entire air intake system are tight. Check for holes in
piping, and repair if needed.
14
3
Access Through Door
in Left Enclosure
Service
Indicator
4
5
15
9
1
2
OR
6
8
7
10
12
11
13
A02258
Item Description
Item
Description
1
Standard Inlet Cap
9
Rubber Reducer with Clamps
2
Pre-Cleaner Inlet Cap
10
Cover Seal
3
Housing
11
Clamp
4
Window
12
Service Cover
5
Reset Button
13
Evacuator™ Valve
6
Housing
14
Rubber Elbow with Clamps
7
Safety Filter
15
Tube
8
Primary Filter
FIGURE 7-6
18CSM7-101