Reference
Only
Manitowoc
Published 12-05-17, Control # 035-23
10-11
18000 SERIVCE/MAINTENANCE MANUAL
TROUBLESHOOTING
10
Problem 9
Load drum (1, 2 or 3) will not raise load, but will lower load.
POSSIBLE CAUSES
Block up limit is opened; Pump is damaged; Control handle is worn;
Maximum bail limit is opened; Node fault; Speed sender is damaged.
CHECKS
See Crane Diagnostics topic in Section 3 to find CAN bus packet numbers.
When applicable switch is enabled…
Boom Block-up . . . . . . . . . . . . . . . . . . . . . . Packet #136, Bank 6 changed by 64 or 128
Fixed Jib Block Up . . . . . . . . . . . . . . . . . . . Packet #132, Bank 6 changed by 64 or 128
Drum 1 Pump Control - Raise . . . . . . . . . . Packet #33, Bank 2 changed by 4
Drum 2 Pump Control - Raise . . . . . . . . . . Packet #33, Bank 2 changed by 16
Drum 3 Pump Control - Raise . . . . . . . . . . Packet #33, Bank 3 changed by 1
All bank numbers increased
by number shown.
Any bank number not increased
by number shown.
Does selected DRUM screen approach 100%
handle control with handle moved back?
Yes
No
Check for problem and
repair limit switch operation,
wiring, or circuit breaker.
Does DRUM screen approach 100% pump control for each pump, with handle moved back?
Yes
No
Consult dealer/factory.
Zero volts at rest and 24 volts present at full speed at
pump EDC with handle moved back?
(See Section 3 - Checking Electrical Inputs/Outputs).
Replace pump(s) EDC
Repair or replace wiring
or consult dealer/factory.
Yes
No
Repair or replace control handle/wiring.
Содержание 18000
Страница 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 18000 ...
Страница 2: ...R e f e r e n c e O n l y ...
Страница 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Страница 210: ...R e f e r e n c e O n l y NOTES SKETCHES AND PHOTOGRAPHS ...
Страница 315: ...R e f e r e n c e O n l y ...
Страница 316: ...R e f e r e n c e O n l y ...