ELECTRIC SYSTEM
18000 SERIVCE/MAINTENANCE MANUAL
3-42
Published 12-05-17, Control # 035-23
•
The normal operating voltage (V) outputs of the control
handle range is 2.4 to 0.5 volts to raise a load and 2.6 to
4.5 volts to lower a load.
NOTE:
With drum control handle D function, raise and
lower voltage is reversed.
•
Control handle Center Switch (CS) command with 0
neutral and 1 active.
•
PUMP A and B command in percent from neutral with +
raise and - lower for each pump.
•
MOTOR command in percent with 0% maximum
displacement and 100% minimum displacement.
•
Measured hoist PRESSURE (psi) at high side pressure
port.
•
Measured drum SPEED in rpm with + raise and - lower.
•
Park BRAKE command with 0 engaged and 1 released.
•
DOS (digital output status) displays a binary number (or
total) if digital output signal is disabled to: pump A -
pump 1 (1), pump B - pump 2 (2), motor 1 (4), motor 2
(8), drum brake (16) or drum pawl (32).
Drum 5
DRUM 5 screen displays the following information:
•
Control HANDLE command in percent from neutral with
+ raise and - lower.
•
The normal operating voltage (V) outputs of the control
handle range is 2.4 to 0.5 volts to raise a load and 2.6 to
4.5 volts to lower a load.
NOTE:
With drum control handle D function, raise and
lower voltage is reversed.
•
Control handle Center Switch (CS) command with 0
neutral and 1 active.
•
PUMP A command in percent from neutral with + raise
and - lower.
•
MOTOR command in percent with 0% maximum
displacement and 100% minimum displacement.
•
Measured hoist PRESSURE (psi) at high side pressure
port.
•
Measured drum SPEED in rpm with + raise and - lower.
•
Park BRAKE command with 0 engaged and 1 released.
•
DOS (digital output status) displays a binary number (or
total) if digital output signal is disabled to: pump A - drum
5 (1), not used (2), drum brake (4), drum pawl (8) or
diverter (16).
Drum 6
DRUM 6 screen displays the following information:
•
Control HANDLE command in percent from neutral with
+ raise and - lower.
•
The normal operating voltage (V) outputs of the control
handle range is 2.4 to 0.5 volts to raise a load and 2.6 to
4.5 volts to lower a load.
NOTE:
With drum control handle D function, raise and
lower voltage is reversed.
•
Control handle Center Switch (CS) command with 0
neutral and 1 active.
•
PUMP A command in percent from neutral with + raise
and - lower.
•
MOTOR command in percent with 0% maximum
displacement and 100% minimum displacement.
•
Measured hoist PRESSURE (psi) at high side pressure
port.
•
Measured drum SPEED in rpm with + raise and - lower.
•
Park BRAKE command with 0 engaged and 1 released.
•
DOS (digital output status) displays a binary number (or
total) if digital output signal is disabled to: pump A (1),
motor (2), drum brake (4) or drum pawl (8).
Swing
(Crane)
The SWING screen displays the following information:
•
Control HANDLE command in percent from neutral with
+ right and - left.
•
The normal operating voltage (V) outputs of the control
handle range is 2.4 to 0.5 volts for left swing and 2.6 to
4.5 volts for right swing.
HANDLE
PUMP A
MOTOR
+/-0 %
+/-0 %
0 %
0.0 V
0
CS
PRESS
SPEED
BRAKE
DOS
0 psi
+/-0 rpm
0
0
DRUM 5
HANDLE
PUMP A
MOTOR
+/-0 %
+/-0 %
0 %
0.0 V
0
CS
PRESS
SPEED
BRAKE
DOS
0 psi
+/-0 rpm
0
0
DRUM 6
HANDLE
PUMP
BRAKE
LOCK
+/-0 %
+/-0 %
0 %
0
0.0 V
0
CS
0 psi
RT PRES
LT PRES
DOS
0 psi
0 psi
0
SWING
Содержание 18000
Страница 1: ...R e f e r e n c e O n l y Service Maintenance Manual Manitowoc 18000 ...
Страница 2: ...R e f e r e n c e O n l y ...
Страница 4: ...R e f e r e n c e O n l y THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH ...
Страница 210: ...R e f e r e n c e O n l y NOTES SKETCHES AND PHOTOGRAPHS ...
Страница 315: ...R e f e r e n c e O n l y ...
Страница 316: ...R e f e r e n c e O n l y ...