E.  Ember Placement

WARNING!  Risk of Explosion! 

Follow ember place-

ment instructions. DO NOT place ember directly over 

burner ports. Replace ember material annually. Improp-

erly placed ember material interferes with proper burner 

operation.

Place the Ember Material

See Figures 11.3.  Place a small amount of 1/2 in. diam

-

eter pieces (dime-size) of ember material on the burner 

top.  Be careful not to cover burner ports. It is not neces

-

sary to use the entire bag. Save the remaining amount 

for future use.

WARNING! Risk of Explosion! 

Follow ember placement 

instructions. DO NOT place embers directly over burner 

ports. Replace ember material annually. Improperly placed 

embers interfere with proper burner operation.

Ember material is shipped with this gas appliance. To place 

the ember material:

•  Embers CANNOT be placed directly over ports. Care 

should be taken not to cover the lighting trail of ports 

(from back to front). 

•  Place dime-size pieces of Glowing Embers®  just in front 

of the port trail, but not on or in between the ports. See 

Figure 11.3. Care should be taken so that the ports are 

not covered. Failure to follow this procedure will likely 

cause lighting and sooting problems.

C.  Clean the Appliance

Clean/vacuum any sawdust that may have accumulated 

inside the firebox or underneath in the control cavity.

Figure 11.3  Placement of Embers

= LAVA ROCK
= EMBERS

= NO EMBERS IN THIS AREA

D.  Install Optional Glass or Fiber Refractory

Optional fiber or glass refractory kits are available for this 

model. Follow the instructions supplied with the kit to in

-

stall the refractory.

Содержание MERID36

Страница 1: ...ent Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in se...

Страница 2: ...ion Minimum Clearances 13 B Chimney Diagram 14 C Approved Pipe 15 D Use of Elbows 16 E Measuring Standards 17 F Vent Diagrams 17 5 Vent Clearances and Framing A Pipe Clearances to Combustibles 32 B Wa...

Страница 3: ...AC provided to the appliance ___________________________ Switch wires properly installed ___________________________ Gas Section 9 Pg 48 49 Proper appliance for fuel type ___________________________ W...

Страница 4: ...her flame proofed or not or plastered or unplastered shall be considered combustible materials G Electrical Codes NOTICE This appliance must be electrically wired and grounded in accordance with local...

Страница 5: ...ly vented gas fu eled heating appliance or equipment The sign shall read in print size no less than one half 1 2 in in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB STRUCTIONS Inspection The state...

Страница 6: ...be sure that the following tools and building supplies are available Tape measure Framing material Pliers Non corrosive leak check solution Hammer Phillips screwdriver Gloves Framing square Voltmeter...

Страница 7: ...rts could impair safe operation DO NOT install damaged in complete or substitute components Keep appliance dry Hearth Home Technologies disclaims any responsibility for and the warranty will be voided...

Страница 8: ...2 216 8 1 2 216 N 2 7 8 73 2 7 8 73 O 8 1 2 216 8 1 2 216 P 1 25 1 25 Q 40 7 8 1038 42 7 8 1089 R 21 9 16 548 23 5 8 600 S 32 813 39 991 T 14 3 16 360 14 3 16 360 U 15 3 8 391 15 3 8 391 V 6 152 6 152...

Страница 9: ...to Section 10 for finishing details A B C D E F G CRD36 MERIDPLA36IN IL in 28 5 8 23 3 16 37 1 16 1 1 2 6 3 16 32 1 4 33 3 4 mm 727 589 941 38 157 819 857 CRD42 MERIDPLA42IN IL in 35 5 8 25 1 8 44 1...

Страница 10: ...vary due to individual design preference Figure 3 3 Appliance Locations A B C D E F G H MERID36IN MERID36IL in 51 42 72 56 5 8 See Section 10 B Mantel Projections 22 17 3 4 8 mm 1295 1067 1829 1438 5...

Страница 11: ...ONS Models A B C D E F G H I J Rough Opening Width Rough Opening Height Rough Opening Depth Rough Opening Width Clearance to Ceiling Combustible Floor Combustible Flooring Behind Appliance Sides of Ap...

Страница 12: ...ionally in regions where cold air infiltration may be an issue the inside surfaces may be sheetrocked and taped or an equivalent method may be used to achieve maximum air tightness To further prevent...

Страница 13: ...OWEST DISCHARGE OPENING 4 Termination Location and Vent Information Fire Risk Maintain vent clearance to combustibles as specified DO NOT pack air space with insulation or other materials Failure to k...

Страница 14: ...V V V M H or i V G X V H A V V H Electrical Service V K V K V L C V N 6 inches non vinyl sidewalls 12 inches vinyl sidewalls O 18 inches non vinyl soffit and overhang 48 inches vinyl soffit and overha...

Страница 15: ...c tion 12 A for vent component information and dimensions DO NOT mix pipe fittings or joining methods from differ ent manufacturers The pipe is tested to be run inside an enclosed wall There is no req...

Страница 16: ...E E F F E C T I V E L E N G T H Y X X X DVP Pipe Effective Length Rise Run Inches Millimeters Inches Millimeters DVP4 4 102 2 3 4 70 DVP6 6 152 4 1 4 108 DVP12 12 305 8 1 2 216 DVP24 24 610 17 432 DVP...

Страница 17: ...face Figure 4 7 Measure to Top of Last Section of Pipe General Rules SUBTRACT 3 ft from the total H measurement for each 90 elbow installed horizontally SUBTRACT 1 1 2 ft from the total H measurement...

Страница 18: ...rtical section of SLP series vent pipe A DVP SLP24 adapter may also be used with a 24 inch vertical section of SLP series vent pipe After the 48 inch vertical section the venting table rules must be f...

Страница 19: ...in 152 mm 4 ft 1 2 m 1 ft 305 mm 6 ft 1 8 m 1 1 2 ft 457 mm 10 ft 3 0 m 2 ft 610 m 15 ft 4 6 m 2 1 2 ft 762 mm 20 ft 6 1 m 3 ft 914 mm 25 ft 7 6 m V1 H1 40 ft 12 2 m Maximum H1 25 ft 7 6 m Maximum ME...

Страница 20: ...m 2 ft 610 mm 11 ft 3 35 m 2 1 2 ft 762 mm 19 ft 5 8 m 3 ft 914 mm 22 ft 6 7 m V1 H1 H2 40 ft 12 2 m Maximum H1 H2 22 ft 6 7 m Maximum V1 1 ft 305 mm Minimum MERID42IN MERID42IL V1 Minimum H1 H2 Maxim...

Страница 21: ...Three Elbows V1 Min H1 Max V2 Min H2 Max Elbow only 2 ft 610 mm 0 in 0 mm 1 ft 305 mm 6 in 152 mm 3 ft 914 mm 6 in 152 mm 2 ft 610 mm 1 ft 305 mm 6 ft 1 8 m 1 ft 305 mm 6 ft 1 8 m 2 ft 610 mm 11 ft 3...

Страница 22: ...2IL Installation Manual 2517 980 Rev C 3 18 Top Vent Vertical Termination No Elbow Figure 4 13 Note If installing a vertical vent termination off the top of the ap pliance the flue restrictor should b...

Страница 23: ...eces on the vent at the setting selected in step 2 and secure in place by using two self tapping screws See Figure 4 14 4 Reinstall the exhaust baffle Top Vent Vertical Termination continued Note If t...

Страница 24: ...4 16 Top Vent Vertical Termination continued V1 H1 Maximum V2 V1 V2 Min Elbow only 2 ft 610 mm 6 in 152 mm 6 ft 1 8 m 2 ft 610 mm 11 ft 3 4 m 3 ft 914 mm 16 ft 4 9 m 4 ft 1 2 m 20 ft 6 1 m V1 V2 H1 40...

Страница 25: ...ly 1 ft 305 mm 1 ft 305 mm 6 in 152 mm 2 ft 610 mm 2 ft 610 mm 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 2 ft 610 mm 4 ft 1 2 m 4 ft 1 2 m 3 ft 914 mm 9 ft 2 7 m 9 ft 2 7 m 4 ft 1 2 m 18 ft 5 5 m 18 ft 5 5...

Страница 26: ...26 Majestic MERID36IN MERID36IL MERID42IN MERID42IL Installation Manual 2517 980 Rev C 3 18 Figure 4 18 Rear Vent Horizontal Termination No Elbow H1 16 in 406 mm Maximum H1...

Страница 27: ...m 12 ft 3 7 m 3 ft 914 mm 4 ft 1 2 m 17 ft 5 2 m 20 ft 6 1 m V1 H1 H2 40 ft 12 2 m Maximum H1 3 ft 914 mm Maximum H1 H2 20 ft 6 1 m Maximum H1 H2 V1 INSTALLED HORIZONTALLY H3 H1 H2 V1 H1 Maximum V1 Mi...

Страница 28: ...mm 1 ft 305 mm 3 ft 914 mm 2 ft 610 mm 5 ft 1 5 m 3 ft 914 mm 7 ft 2 1 m 4 ft 1 2 m 8 ft 2 4 m 5 ft 1 5 m 8 ft 2 4 m V1 H1 40 ft 12 2 m Maximum H1 8 ft 2 4 m Maximum V1 Minimum H1 H2 Maximum Back to B...

Страница 29: ...m 10 ft 3 1 m 8 ft 2 4 m V1 H1 H2 H3 40 ft 12 2 m Maximum No specific restrictions on this value EXCEPT V1 H1 H2 H3 cannot exceed 40 ft 12 2 m Maximum H1 H2 H3 8 ft 2 4 m Maximum H1 Maximum V1 Minimu...

Страница 30: ...NING Risk of Fire Coaxial to colinear venting con figuration may only be used in existing non combustible chimney Installation in any other venting application could cause fire Prior to installing the...

Страница 31: ...ons included with DVP 2SL kit Attach the DV 46DVA GCL adapter to the appliance starting collar with 3 1 2 in self tapping screws See Figure 4 27 Rear Vent Remove the rear seal cap and insulation if eq...

Страница 32: ...s than 4 in the existing heat shields must be field trimmed If wall thickness is greater than 7 1 4 in a DVP HSM B will be required SLP heat shield designed to be used on a wall 4 3 8 in to 7 5 8 in 1...

Страница 33: ...a heat shield refer to Section 12 A attached to them See Section 7 F for information for regarding the instal lation of a horizontal termination cap Non Combustible Wall Penetration If the hole being...

Страница 34: ...u lation around the vent Insulation must be kept back from the pipe to prevent overheating Figure 5 4 Installing Ceiling Firestop Figure 5 5 Installing the Attic Shield INSTALL ATTIC INSULATION SHIELD...

Страница 35: ...tion Top Vent Figure 6 1 Generic Fireplace Shown Cut the seal cap strap across the rectangles next to the disk Figure 6 2 Generic Fireplace Shown Remove the white gasket material covering the seal cap...

Страница 36: ...wn To attach the first section of vent pipe make sure to use the fiberglass gasket in the manual bag to seal between the first vent component and the outer fireplace wrap Use 2 self tapping screws to...

Страница 37: ...E Additional clearances are required for heat management systems installations Provisions must be made in advance to ensure fit within the framing Locate the heat management ports on the left and righ...

Страница 38: ...n air space clearance could cause overheating and fire The diagram shows how to properly square position and secure the appliance See Figures 6 12 and 6 13 Nailing tabs are provided to secure the appl...

Страница 39: ...um continuous exposure rating including the slip section that connects directly to the horizontal ter mination cap Apply a bead of silicone sealant 300 F minimum con tinuous exposure rating inside the...

Страница 40: ...f silicone sealant 300 F minimum con tinuous exposure rating to the outside of connecting joint after joining sections OR Apply aluminum foil tape 300 F minimum continuous exposure rating to the outsi...

Страница 41: ...arefully to separate the pieces of pipe Figure 7 11 Align and Disassemble Vent Sections Figure 7 10 Rotate Seams for Disassembly C Secure the Vent Sections Vertical runs originating off the top of the...

Страница 42: ...M HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Figure 7 14 insert Bolt into Brackets NOTICE Failure to properly caulk the roof flashing and pipe seams could permit entry of water Caulk the gap between...

Страница 43: ...lds must overlap 1 1 2 in 38 mm mini mum There are two sections of the heat shield One section is factory attached to the wall shield firestop The other section is factory attached to the cap See Figu...

Страница 44: ...of a cap shield to prevent anything or anyone from touching the hot cap NOTICE For certain exposures which require superior resistance to wind driven rain penetration a flashing kit and HRC caps are...

Страница 45: ...This appliance may be used with a wall switch wall mounted thermostat and or a remote control Wiring for optional Hearth Home Technologies ap proved accessories should be done now to avoid re construc...

Страница 46: ...tion System Wiring Wire the appliance junction box to 110 120 VAC for proper operation of the appliance WARNING Risk of Shock or Explosion DO NOT wire IPI controlled appliance junction box to a switch...

Страница 47: ...At the switch box connect the black hot wire and red switch leg wire to the wall switch as shown At the appliance connect the black hot white neutral and green ground wires to the junction box as sho...

Страница 48: ...oos ened during shipping and handling WARNING Risk of Fire DO NOT change valve settings This valve has been preset at the factory WARNING Risk of Fire or Explosion High pressure will damage valve Low...

Страница 49: ...ghten the wing nut NOTICE If sooting occurs provide more air by opening the air shutter MODEL GAS TYPE MIN VENT RUN MAX VENT RUN MERID36IN NG 1 8 in Full Open MERID36IL PROPANE 3 8 in Full Open MERID4...

Страница 50: ...to Figure 10 1 and Figure 10 2 WARNING Risk of Fire DO NOT apply combustible materials beyond the minimum clearances Comply with all minimum clearances to combustibles as specified in this manual Ove...

Страница 51: ...__ then B maximum is_____ A Inches 2 7 16 3 7 16 4 7 16 5 7 16 6 7 16 7 7 16 Millimeters 62 87 113 138 164 189 B Inches 1 2 3 4 5 Millimeters 25 51 76 102 127 Note Measurement is taken from top of the...

Страница 52: ...NG STRIP NOT USED See Figure 10 10 for removal instructions NON COMBUSTIBLE FINISHING MATERIAL 1 IN MAX CRD36 CRD42 Overlap Fit 0 1 Inch Thick Finishing Method Non Combustible Finish Materials Remove...

Страница 53: ...nches Thick FINISHING STRIP NOT USED See Figure 10 10 for removal instructions NON COMBUSTIBLE FINISHING MATERIAL 0 6 IN MAX TOP OF APPLIANCE OPENING Figure 10 8 Inside Fit Decorative Front Finish Mat...

Страница 54: ...L Installation Manual 2517 980 Rev C 3 18 FINISHING STRIPS REMOVED Figure 10 10 Removing Finishing Strips Removal of Finishing Strips NOTICE Remove finishing strips before firing appliance Remove glas...

Страница 55: ...talling the embers logs and lava rock The grate tine on the right hand side should be parallel to the burner See Figure 11 2 If the grate is not parallel to the burner contact your dealer A Fixed Glas...

Страница 56: ...ally Improperly placed embers interfere with proper burner operation Ember material is shipped with this gas appliance To place the ember material Embers CANNOT be placed directly over ports Care shou...

Страница 57: ...701 Log B SRV2397 702 Log C SRV2397 703 CAUTION Logs are fragile handle with care Figure 4 LOGSDBDV36 Log Pin Locations LOG A LOG B LOG F NOTICE To simplify the installation process positively identi...

Страница 58: ...he notch on Log C Place the notch over the center grate tine as shown in Figure 7 Slide the log toward the front of the appliance until the portion of the log closest to the rear of the firebox contac...

Страница 59: ...og C The back of Log E should be flush with the back of Log A See Figure 9 Figure 9 Log E Installed A A B C D E E F Figure 10 Log E Installed LOG F RESTS AGAINST PIN AND CONTACTS GRATE 6 LOG F Place L...

Страница 60: ...2 Log Set Assembled LOG A LOG E3 LOG B LOG E2 LOG F LOG C NOTICE To simplify the installation process positively identify each individual log before beginning installation Reference Figure 1 and 2 for...

Страница 61: ...og C Place the notch over the center grate tine and rear of log between the right grate tine and Log Pin C as shown in Figure 7 Move notched end of log forward until it stops then rotate rear of log t...

Страница 62: ...the log should be positioned against the pin indicated in Figure 4 for Log E2 The top side should rest against Log A The base end of Log E2 should be approximately one inch from the left side of the f...

Страница 63: ...sition switch on the IFT ECM is switched to the REMOTE position Detailed Operat ing Instructions for the IFT ECM are provided in Sec tion 3 J of the Owner s Manual Figure 11 4 IFT ECM If this applianc...

Страница 64: ...m 11 3 8 in 289 mm 1 1 4 in 32 mm 9 1 4 in 235 mm 13 1 4 in 337 mm 1 2 in TYP DVP90ST 90 Elbow 10 in 254 mm 10 in 254 mm 1 in 25 mm DVP FS Ceiling Firestop DVP45 45 Elbow DVP Pipe see chart Effective...

Страница 65: ...m of 1 1 2 in 38 mm The heat shield is designed to be used on a wall 4 in to 7 1 4 in 102 mm to 184 mm thick If wall thickness is less than 4 in 102 mm the existing heat shields must be field trimmed...

Страница 66: ...n 337 mm RF12 Roof Flashing Cap Shield DRC RADIUS 13 7 8 in 352 mm 9 1 2 in 241 mm 14 in 356 mm COOL ADDM Cap Shield 11 5 8 in 295 mm 5 3 4 in 146 mm 7 1 8 in 181 mm 12 1 8 in 308 mm DVP BEK2 DVP HPC...

Страница 67: ...ination Cap Highwind 14 in 356 mm 12 in 305 mm 12 1 8 in 314 mm 7 1 8 in 181 mm 8 3 4 in 222 mm 1 5 8 in 41 mm 16 7 8 in 429 mm DVP HPC High Performance Cap 1 in 25 mm 14 in 356 mm 3 8 in 10 mm 1 in 2...

Страница 68: ...CAP 13 in 330 mm 15 in 381 mm 8 1 8 in 206 mm 10 7 8 in 276 mm 10 1 2 in 267 mm 3 87 Effective Length 5 3 4 to 8 3 8 in 146 to 213 mm 5 1 2 in 140 mm 8 3 8 in 213 mm Figure 12 5 DVP Vent Components Fi...

Страница 69: ...m 12 1 2 IN 318 mm 20 3 4 IN 527 mm 13 5 8 IN 346 mm EFFECTIVE LENGTH 32 IN 813 mm MIN 35 IN 889 mm MAX A Vent Components Diagrams continued Figure 12 6 PVI SLP B Vent Components SLP LPC SLP Low Profi...

Страница 70: ...3 8 IN 112 mm 10 IN 254 mm 5 1 4 IN 135 mm 2 1 4 IN 57 mm 9 1 2 IN 241 mm 4 3 4 IN 121 mm 2 1 4 IN 57 mm 1 1 2 IN 38 mm 6 1 4 IN 159 mm Front View Top View Side View PVLP BEK Brick Kit Note Wire harn...

Страница 71: ...SLP45 45 Elbow SLP90 90 Elbow Effective Height Length SLP PIPE SLP HVS Horizontal Pipe Support SLP FS Ceiling Firestop SLP WS Wall Shield Firestop DVP SLP24 Adapter 6 1 2 in 165 mm 25 3 16 in 640 mm...

Страница 72: ...ss is greater than 7 1 4 in 184 mm a DVP HSM B will be required Heat Shield Term Cap Minimum Effective Length Maximum Effective Length Trap1 3 1 8 in 4 3 4 in 79 mm 121mm Trap2 5 1 4 in 9 1 4 in 133 m...

Страница 73: ...m 10 7 8 in 276 mm 10 1 2 in 267 mm 3 87 Effective Length 5 3 4 to 8 3 8 in 146 to 213 mm 5 1 2 in 140 mm 8 3 8 in 213 mm SLP HRC SS HORIZONTAL TERMINATION CAP When using DVP TB1 termination cap on to...

Страница 74: ...axial Colinear Appliance Connector 768 380A Stainless Steel Flex Pipe Required DVP 2SL Adapter COAXIAL to COLINEAR VENTING Figure 12 12 Coaxial to Colinear Vent Components SLP HHW2 Horizontal High Win...

Страница 75: ...ur fan See your dealer if you have questions Optional Fiber or Glass Refractory An optional refractory kit is available for this model Contact your dealer if you have questions Printed in U S A Copyri...

Отзывы: