Introduction
1.1.2 AGS
Controller
The AGS controller provides adjustments and the generator’s wiring
connections. Refer to Figure 1-2.
1
AGS Adjustments (x5)
–
The thumb wheel adjustments
allow the AGS to be con
fi
gured to your speci
fi
c system
preferences.
• RUN TIME HOURS
– determines the length of time the
generator runs once it is automatically started.
• START TEMP °F
– allows you to enable and set a
high temperature value that causes the generator to
automatically start.
• START VOLTS DC
– allows you to enable and set a
low battery voltage value that causes the generator to
automatically start.
• CLOCK AM/PM
– determines the correct time, which in
turn allows the Quiet Time feature to function correctly.
• QUIET
TIME
PM/AM
– used to prevent the generator from
starting during speci
fi
c hours.
2
STATUS Indicator
– this bi-color (green or red) LED indicator
illuminates to provide information on AGS operation.
3
TEST Switch
– a momentary pushbutton switch that allows
the AGS system to be tested for correct wiring and generator
start/stop operation.
4
Wiring Terminal Block
– this 8-port friction-
fi
t connector
powers the AGS and connects the generator’s start/stop and
run sense wires.
5
Mounting Flange
– used to secure the inverter to a shelf
or wall.
6
READY Indicator
– this green LED indicator illuminates to
indicate that the AGS is powered and the remote switch is
connected.
7
REMOTE Connection Port (purple label)
– a RJ12 port
which provides the connection point for the remote switch.