© 2016 Sensata Technologies
2
Introduction
1.1 ME-AGS-S
Components/Features
The ME-AGS-S has the following components and features:
• AGS Remote Switch • AGS-S Controller • Communication cable
1.1.1 AGS Remote Switch
The AGS remote switch is the user interface display, and connects to
the AGS controller using the supplied communications cable. Refer
to Figure 1-1.
1
Selector Switch
– allows the AGS system to be enabled/
disabled for automatic generator operation and tested for
correct wiring.
• ENABLE
– activates the AGS to monitor voltage and/or
temperature—uses this information to determine when to
automatically start the generator.
• OFF
– disables the AGS generator start/stop functions.
• TEST
– initiates an automatic generator start/stop
sequence for testing the generator’s wiring and operation.
2
STATUS Indicator
– this bi-color (green or red) LED indicator
illuminates to provide information on AGS operation.
3
Temperature Sensor (internal)
– location of the
internal sensor used to start the generator (based on high
temperature).
Figure 1-1, ME-AGS-S Remote Switch Features
2
1
3
• Compatible with any inverter/charger-based system
• Compatible with most AC or DC generators with either two-wire
or three-wire start controls
• TEST switch provides immediate con
fi
rmation of installation
wiring
• Removable 8-port terminal block for easy wiring and power-
down
• Front panel LED indicators for generator start/stop status and
generator faults