3.5
Agency Approvals
These units are in compliance with the EMC-directive 2014/30/EU,
the PED-directive 2014/68/EU and the ATEX directive 2014/34/EU.
The following approval standards are applicable:
FM3600:2018, FM3610:2010, FM3611:2018, FM3616:2011, FM3810:2018, UL60079-0:2019, ANSI/ISA 60079-11:2014,
ANSI/ISA 60079-15:2012, ANSI/ISA 60079-26:2014, ANSI/NEMA 250:2003, ANSI/IEC 60529:2004, CSA-C22.2 No. 25:2009,
CSA-C22.2 No. 30:2007, CSA- C22.2 No. 94:2001, CSA-C22.2 No. 157:2012, CSA-C22.2 No. 213:2012, CAN/CSA 60079-
0:2019 CAN/CSA 60079-11:2011 CAN/CSA 60079-15:2012 C22.2 No. 60529:R2010, ANSI/ISA 12.27.01, EN/IEC60079-
0:2018, EN60079-11:2012, EN60079-15:2010, EN60079-26:2007, A1:1991-2000, IEC60079-0:2017, IEC60079-
1:2014, IEC60079-11:2011, IEC60079-15:2010, IEC60079-26:2006, ANSI/ISA 12.27.01:2011
3.5.1 Special Conditions of Use
1. The enclosure contains aluminum and is considered to present a potential risk of ignition by impact or
friction. Care must be taken during installation and use to prevent impact or friction.
2. The risk of electrostatic discharge shall be minimized at installation, following the directions given in
the instructions.
3. For installation with ambient temperature of +70 °C, refer to the manufacturer’s instructions for guid-
ance on proper selection of conductors.
4. WARNING — Explosion Hazard: Do not disconnect equipment when flammable or combustible
atmoshpere is present.
Intrinsically Safe
US: FM19US0182X
Class I, II, III, Div 1, Group A, B, C, D, E, F, G, T4...T1
Class I, Zone 0 AEx ia IIC T4...T1 Ga
Ta =-40 ºC to + 70 ºC
Type 4X, IP66/67
Canada: FM19CA0094X
Class I, II, III, Div 1, Group A, B, C, D, E, F, G, T4...T1
Zone 0, Ex ia IIC T4...T1 Ga
Ta =-40 ºC to + 70 ºC
Type 4X, IP66/67
ATEX – FM19ATEX0197X:
II 1 G Ex ia IIC T4 Ga
Ta = -40 ºC to +70 ºC
IP 66/67
IEC – IECEx FMG 19.0037X:
Ex ia IIC T4 Ga
Ta = -40 ºC to +70 ºC
IP 66/67
Non- Incendive
US: FM19US0182X
Class I, II, III, Div 2, Group A, B, C, D, E, F, G, T4...T1
Class I, Zone 2 AEx nA IIC T4...T1 Gc
Ta =-15 ºC to + 70 ºC
Type 4X, IP66/67
Canada: FM19CA0094X
Class I, II, III, Div 2, Group A, B, C, D, E, F, G, T4...T1
Zone 2, Ex nA IIC T4...T1 Gc
Ta =-15 ºC to + 70 ºC
Type 4X, IP66/67
ATEX – FM19ATEX0199X:
II 3 G Ex nA IIC T4...T1 Gc
Ta = -15 ºC to +70 ºC
IP 66/67
IEC – IECEx FMG 19.0037X:
Ex nA IIC T4 Gc
Ta = -15 ºC to + 70 ºC
IP 66/67
59