background image

 

Enrange MLTX2 Intrinsically Safe 

Transmitter Instruction Manual 

April 2019 

Page 31 of 44 

 

PROGRAMMING WITH RCP 

 
Read the section of the MLTX2 manual regarding additional operational features to familiarize yourself 
with the features listed below. The MLTX2 transmitter can be programmed using the optional RCP (Radio 
Control Programmer) software through the programming adapter (inside a HAZLOC area) or directly to 
the transmitters USB connection outside of the HAZLOC area.   
 
Magnetek RCP software makes the programming of the MLTX2 transmitter easier and allows the 
programmer to store all of the MLTX2 settings in files for later use or reference. The RCP software also 
allows the programmer to customize the MLTX2 transmitter display with language descriptions that are 
project or machine-specific. Help is provided for each function at the bottom of the RCP screen. The RCP 
software allows you to select frequency, access code, transmitter power, as well as CAN configuration. 
Follow the steps below: 
 

Install the RCP Software 

 
Install the RCP software onto your computer. The software is self-installing; simply insert the jump drive 
into any available USB port and follow the onscreen prompts. Refer to the installation instruction sheet for 
help. You will be prompted to enter an activation code. The code can be found on the jump drive’s outer 
case and on the installation instructions. The software cannot be used without this code.  
 

Run the RCP Software 

 
After installation of the RCP Software, double-click the RCP icon to launch the program. 
 

 

 

Click on New Project or Open Project 

 
Select “New Project” if you are creating a new program file. Select “Open Project” if you want to retrieve 
an existing program file. 

A list of recent projects will appear under “Open Project.”  Clicking on one of 

these will open that project. It is recommended that you create a folder in which to save all programming 
files.   

Содержание Telemotive MLTX2

Страница 1: ...Enrange MLTX2 Transmitter Intrinsically Safe Radio Remote Control April 2019 Part Number 198 80202 2001 R04 2019 Magnetek...

Страница 2: ...288 8178 Website www magnetek com E mail mhcustomerservice magnetek com Fax Numbers Main 800 298 3503 Sales 262 783 3510 Service 262 783 3508 Canada Service Information 161 Orenda Road Unit 1 Brampto...

Страница 3: ...TCH For Emergency Stopping Only 16 3 4 POWER STATUS AND BATTERY LED 17 3 5 OPTIONAL GRAPHIC USER INTERFACE 17 3 6 NORMAL OPERATING MODE WITH STANDARD STATUS LED S 17 3 6 1 Transmitters Equipped with S...

Страница 4: ...TRANSMITTER RF CHANNEL CONFIGURATION SETTINGS 40 6 1 FCC ATEX IECEx STATEMENTS 40 6 2 CHANNEL AND FREQUENCY DESIGNATIONS BY COUNT 41 6 3 433 MHz Telemotive Legacy Channel Set TMS and TDMA 42 7 GENERA...

Страница 5: ...in this manual do not take precedence over any of the following requirements relating to cranes hoists and lifting devices Instructions manuals and safety warnings of the manufacturers of the equipme...

Страница 6: ...perating or maintenance procedure practice etc which if not strictly observed could result in damage to or destruction of equipment or loss of functional effectiveness Cautions are highlighted as show...

Страница 7: ...WARNING SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY 2 1 GENERAL Radio controlled material handling equipment operates in several directions Cranes hoists lifting devices and other material...

Страница 8: ...conditions test the transmitter emergency stop and all warning devices prior to operation testing should be done on each shift without a load be thoroughly trained and knowledgeable in proper and safe...

Страница 9: ...handling equipment Spare transmitters should be stored in a secure storage space and only removed from the storage space after the current transmitter in use has been turned OFF taken out of the serv...

Страница 10: ...UTS OF THIS PRODUCT ARE NOT DESIGNED TO INTERFACE DIRECTLY TO TWO STATE SAFETY CRITICAL MAINTAINED FUNCTIONS I E MAGNETS VACUUM LIFTS PUMPS EMERGENCY EQUIPMENT ETC A MECHANICALLY LOCKING INTERMEDIATE...

Страница 11: ...y such as Controlling the work environment humidity level to minimize generation of static electricity Protect the transmitter from direct airflow Touch the transmitter with an insulating object or gl...

Страница 12: ...ING THE TRANSMITTER FAMILIARIZE YOURSELF WITH ALL SAFETY INFORMATION IN THIS MANUAL THE CORRESPONDING RECEIVER SYSTEM MANUAL APPROPRIATE MANUAL SUPPLEMENTS AND ANY OTHER LOCAL STATE OR FEDERAL RULES O...

Страница 13: ...nt batteries to maintain intrinsically safe operation WARNING ONLY OPERATE THE TRANSMITTER IN HAZARDOUS ENVIRONMENTS WITH THE APPROVED BATTERIES FAILURE TO USE THE APPROVED BATTERIES COULD RESULT IN S...

Страница 14: ...When placing the battery pack into the MLTX2 battery pocket ensure that the pack is fully seated and that the thumb screw is tightened down to hold the battery pack in place Figure 4 Installation of B...

Страница 15: ...itself down After a successful initialization the MLTX2 will enter normal operation mode and display the normal operating status LED indications See Section 3 6 for more information on the normal ope...

Страница 16: ...red during the transmitter s power down process Once the power down process is complete the transmitter will turn off and the status LED will not be on NOTE You must place the OFF ON START switch to t...

Страница 17: ...l is low 3 6 1 Transmitters Equipped with Separate Power Status and Battery LED Indicators 3 6 1 1 Watch Dog Indicator Steady Slow Blinking Green Power Status LED The blinking Power Status LED represe...

Страница 18: ...tinuously blinking at all times If the LED is not blinking the transmitter will need to be rebooted to operate properly 3 6 2 2 Low Battery Level Indicator Rapidly Blinking Red Status Battery LED The...

Страница 19: ...terface screen Battery life is displayed in 5 increments NOTE If using a different battery pack than what the unit originally shipped with the battery life indicator will be inaccurate unless the dip...

Страница 20: ...desired motor functions operate the Joystick or Paddle Lever that corresponds to the desired motion To activate higher speed functions for those transmitter models so equipped operate the Joystick or...

Страница 21: ...mitter Instruction Manual April 2019 Page 21 of 44 WARNING PROGRAMMING THROUGH THE USB PORT IS TO BE DONE SOLELY BY MAGENETK SERVICE PERSONNEL FAILURE TO FOLLOW THIS WARNING COULD RESULT IN SERIOUS IN...

Страница 22: ...TANDARD STATUS LED WARNING TO PREVENT IGNITION OF FLAMMABLE OR COMBUSTIBLE ATMOSPHERES AND TO AVOID COMPROMISING INTRINSIC SAFETY OF THE EQUIPMENT READ UNDERSTAND AND ADHERE TO THE LIVE MAINTENANCE PR...

Страница 23: ...ock as Viewed Through USB IR Port NOTE The dip switch block switches are oriented so that the Off position is next to the number designator and the On position is up or away from the number designator...

Страница 24: ...channel set by the IR configuration receiver function will not be used unless the memory override dip switch is set to ON When the RF channel from memory override is NOT enabled the dip switch positio...

Страница 25: ...ith a compatible receiver the Power Status and Battery LED s will continue to blink alternately To cancel the IR configuration receiver without a successful link move the OFF ON START toggle to the OF...

Страница 26: ...le to the Start position and release If the link is successful the LED will stop blinking and the transmitter will shut down The new settings obtained from the IR configuration function will take effe...

Страница 27: ...be controlled by the transmitter The Access Code in the MLTX2 transmitter must match the receiver Access Code or dip switches If the Access Codes settings on the receiver and transmitter do not match...

Страница 28: ...sabled setting is selected the user will go directly into setup mode without being prompted to enter a password Magnetek strongly recommends enabling the setup mode password setting to prevent unautho...

Страница 29: ...he graphic user interface will display Err Project ID when an IR link is attempted The IR link will not be successful and the access code and channel information in the transmitter will not be changed...

Страница 30: ...ation changes made the Exit Without Save option can be selected NOTE None of the changes will be saved upon selection of this option The transmitter will start up with the last saved configuration set...

Страница 31: ...tom of the RCP screen The RCP software allows you to select frequency access code transmitter power as well as CAN configuration Follow the steps below Install the RCP Software Install the RCP softwar...

Страница 32: ...program selecting a project type will display a picture of the product for verification Receive Device Data Checkbox At the bottom of the New Project window there is a check box that allows the user t...

Страница 33: ...OMMENDS THAT THE RECEIVE DEVICE DATA CHECKBOX BE LEFT CHECKED This screen also allows the programmer to create a specific name for the device to help keep track of device settings and changes It is re...

Страница 34: ...password This page may also be used by the user to synchronize the internal clock on the transmitter with the connected PC or manually set the clock date NOTE Changing any of these details will requir...

Страница 35: ...selectable through the pull down menu This function is used to prevent interference with other radio devices The user selectable channels for 400 MHz and 900 MHz systems are 1 through 32 See Section 6...

Страница 36: ...NABLING THE PASSWORD FUNCTION ALLOWS THE TRANSMITTER SETTINGS TO BE MODIFIED BY ANY UNAUTHORIZED USERS IMPROPER TRANSMITTER SETTINGS COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT Bac...

Страница 37: ...communication settings Source Address This is the address that the MLTX2 will use as the source address when transmitting messages on the CAN bus network Protocol This pull down menu allows the user...

Страница 38: ...e menu Sending a Program to the MLTX2 WARNING AFTER EVERY PROGRAMMING OF THE TRANSMITTER TEST THE UNIT BY UTILIZING THE APPROPRIATE RECEIVER IF THE RECEIVER DOES NOT RESPOND DO NOT ACTIVATE A FUNCTION...

Страница 39: ...turn the radio Transmitter on 2 Click Receive and follow on screen prompts 3 RCP will confirm reception and automatically display current programming in the MLTX2 unit Reading the RCP Software Version...

Страница 40: ...003 for details regarding the hazardous location approvals for this product Compliance Statement Part 15 19 This device complies with Part 15 of FCC rules Operation is subject to the following two con...

Страница 41: ...24 24 434 150 MHz 25 25 434 200 MHz 26 26 434 250 MHz 27 27 434 300 MHz 28 28 434 350 MHz 29 29 434 400 MHz 30 30 434 450 MHz 31 31 434 500 MHz 32 32 434 550 MHz Table 1 A Channels marked with are ap...

Страница 42: ...38 8 MHz 07 AK07 438 6 MHz 08 AK08 438 4 MHz 09 AK09 438 2 MHz 10 AK10 438 0 MHz 11 AK11 437 8 MHz 12 AK12 437 6 MHz 13 AK13 437 4 MHz 14 AK14 437 2 MHz 15 AK15 437 0 MHz 16 AK16 436 8 MHz 17 AK17 436...

Страница 43: ...rect system RF channel Make sure the transmitter and receiver unit are both set to the same RF channel Incorrect system access code Make sure the transmitter and receiver both have the same access cod...

Страница 44: ...11 2 009 A1 20 10 A12 2011 A2 2013 ATEX spec c informa on Product is in conformity with the EC type examina on cer cate DEMKO14ATEX 1350799X For Equipment Group and Category II 1 G Type of Protec on i...

Отзывы: