Enrange MLTX2 Intrinsically Safe
Transmitter Instruction Manual
April 2019
Page 24 of 44
Figure 8: Dip Switch Positions for RF Channel Selection
The dip switch settings will take effect upon the next power cycle of the transmitter.
NOTE: If using the IR configuration receiver function on transmitters NOT equipped with the optional
graphic user interface, the channel settings will read from the dip switch positions and not from memory
when the channel from memory override function is not enabled. The RF channel set by the IR
configuration receiver function will not be used unless the memory override dip switch is set to ON. When
the RF channel from memory override is NOT enabled, the dip switch positions set the RF channel used
by the transmitter.
NOTE: The transmitters equipped with the optional graphic user interface will read channel settings from
memory and will not respond to dip switch changes for the channel setup.
4.1.3
IR Configuration Receiver
The IR Cfg Recv functionallows the transmitter to link to a compatible receiver by using IR (contact the
factory to determine if your receiver is compatible) and automatically set up the channel and access code
to match the linked compatible receiver.