Enrange MLTX2 Intrinsically Safe
Transmitter Instruction Manual
April 2019
Page 34 of 44
NOTE: HAZLOC systems will not typically have CAN bus networks due to electrical connection hazards.
Unit Info Pages
This page allows the user to view the
receiver’s Project ID and serial number. The user can modify the
transmitter name, access code, RF channel and activate the password. This page may also be used by
the user to synchronize the internal clock on the transmitter with the connected PC or manually set the
clock/date.
NOTE: Changing any of these details will require a reboot of the MLTX2 after the new information has
been sent to the device.
Transmitter Name
The transmitter name field allows the user to create a custom name for the transmitter. The name can be
up to 16 ASCII characters long.
Project ID
This section displays the Project ID for the unit. The Project ID is set by the factory and cannot be
modified by the user.