Enrange MLTX2 Intrinsically Safe
Transmitter Instruction Manual
April 2019
Page 25 of 44
NOTE: If using the IR configuration receiver function on transmitters NOT equipped with the optional
graphic user interface, the channel settings will read from the dip switch positions and not from memory
when the channel from memory override function is not enabled. The RF channel set by the IR
configuration receiver function will not be used unless the memory override dip switch is set to ON. When
the RF channel from memory override is NOT enabled, the dip switch positions set the RF channel used
by the transmitter.
4.1.3.1 IR Configuration Receiver On Transmitters Equipped with Separate Power/Status and
Battery LED Indicators
To utilize the IR configuration receiver function and link to a compatible receiver, push the OFF-ON-
START toggle to the Start position and hold for more than 5 seconds. When the transmitter successfully
enters the IR configuration mode, the Power/Status and Battery LED(s) will blink alternately continuously.
After the LEDs are blinking alternately, point the IR window of the transmitter at the desired receiver to
control and momentarily press the OFF-ON-START toggle to the Start position and release.
If the link is successful, the LEDs will stop blinking and the transmitter will shut down. The new settings
obtained from the IR configuration function will take effect upon the next power cycle of the transmitter.
If the link is unsuccessful with a compatible receiver, the Power/Status and Battery LED(s) will continue to
blink alternately.
To cancel the IR configuration receiver without a successful link, move the OFF-ON-START toggle to the
OFF position.
4.1.3.2 IR Configuration Receiver On Transmitters Equipped with Single Status/Battery LED
Indicator
To utilize the IR configuration receiver function and link to a compatible receiver, push the OFF-ON-
START toggle to the Start position and hold for more than 5 seconds. When the transmitter successfully
enters the IR configuration mode, the Status/Battery LED will blink continuously. After the LED is
blinking, point the IR window of the transmitter at the desired receiver to control and momentarily press
the OFF-ON-START toggle to the Start position and release.
If the link is successful, the LED will stop blinking and the transmitter will shut down. The new settings
obtained from the IR configuration function will take effect upon the next power cycle of the transmitter.
If the link is unsuccessful with a compatible receiver, the Status/Battery LED will continue to blink.
To cancel the IR configuration receiver without a successful link, move the OFF-ON-START toggle to the
OFF position.
4.1.4
RCP IR Configuration on Transmitters without a Display
4.1.4.1 Transmitters Equipped with Separate Power/Status and Battery LED Indicators
The RCP IR Configuration feature (supported in common code version 6.2 and greater) allows the
transmitter configuration to be read and written through the IR Adapter port. Contact customer service to
determine if your transmitter is compatible. You will also need to have an IR Adapter available to
configure the device.