IMPULSE•G+ Mini Advanced Instruction Manual – March 2014
5-33
Tuning
These parameters help tune the motor for your application, which include Torque Compensation and
S-Curve characteristics for smoother transition during machine acceleration and deceleration. Below
are the parameters included in this section.
•
D1 DC Injection
•
D2 Automatic Slip Compensation
•
D3 Torque Compensation
•
D8 Dwell Function
•
D9 S-Curve Acceleration/Deceleration
•
D10 Carrier Frequency
•
D11 Hunting Prevention
DC Injection
DC Injection can be used to stop a motor whose rotational direction is uncertain at start-up.
With Decel to Stop enabled (B03.03 = 00), upon removal of the run command the IMPULSE•G+
Mini drive controls motor deceleration according to the Decel Time setting, until output frequency
reaches the DC Injection Braking Start Frequency (D01.01 setting). Then the drive output is turned
off and DC injection current is applied to the motor. The effective DC injection time and current
should be set to provide adequate stopping without excessive motor heating. The DC injection
voltage is determined by the DC injection braking current and motor impedance.
Figure 5-20: DC Braking Sequence
Parameter
Code
Name
Function
Range
Initial Value
Access
Level
D01.01
DC Injection Start Frequency DC Injection braking
frequency start.
0.0–10.0 Hz
0.5
Basic/Adv
D01.02
DC Injection Current
% of Inverter rated current.
0–75%
50
Basic/Adv
D01.03
DC Injection Time @ Start
DC Injection braking time.
0.00–10.00 sec
0.00
Basic/Adv
D01.04
DC Injection Time @ Stop
DC Injection braking time at
stop.
0.00–10.00 sec
0.05
Basic/Adv
Содержание 2001-G+M
Страница 2: ......
Страница 9: ...C h a p t e r 1 Introduction...
Страница 10: ...IMPULSE G Mini Advanced Instruction Manual March 2014 1 2 This page intentionally left blank...
Страница 16: ...IMPULSE G Mini Advanced Instruction Manual March 2014 1 8 This page intentionally left blank...
Страница 17: ...C h a p t e r 2 Installation...
Страница 18: ...IMPULSE G Mini Advanced Instruction Manual March 2014 2 2 This page intentionally left blank...
Страница 25: ...C h a p t e r 3 Wiring...
Страница 26: ...IMPULSE G Mini Advanced Instruction Manual March 2014 3 2 This page intentionally left blank...
Страница 38: ...IMPULSE G Mini Advanced Instruction Manual March 2014 3 14 This page intentionally left blank...
Страница 39: ...C h a p t e r 4 Getting Started...
Страница 40: ...IMPULSE G Mini Advanced Instruction Manual March 2014 4 2 This page intentionally left blank...
Страница 60: ...IMPULSE G Mini Advanced Instruction Manual March 2014 4 22 This page intentionally left blank...
Страница 61: ...C h a p t e r 5 Programming Features...
Страница 62: ...IMPULSE G Mini Advanced Instruction Manual March 2014 5 2 This page intentionally left blank...
Страница 88: ...IMPULSE G Mini Advanced Instruction Manual March 2014 5 28 Figure 5 17 Swift Lift Timing Diagram...
Страница 153: ...Troubleshooting IMPULSE G Mini C h a p t e r 6...
Страница 154: ...IMPULSE G Mini Advanced Instruction Manual March 2014 6 2 This page intentionally left blank...
Страница 165: ...IMPULSE G Mini Advanced Parameter Listing A p p e n d i x A...
Страница 166: ...IMPULSE G Mini Advanced Instruction Manual March 2014 A 2 This page intentionally left blank...
Страница 190: ...IMPULSE G Mini Advanced Instruction Manual March 2014 A 26 This page intentionally left blank...