![background image](http://html1.mh-extra.com/html/magnetek/2001-g-m/2001-g-m_instruction-manual_3598661089.webp)
IMPULSE•G+ Mini Advanced Instruction Manual – March 2014
5-29
Torque Limit (Open Loop Vector Only)
IMPULSE•G+ Mini dynamically controls the torque output of the motor at all times when the
control method is set to Open Loop Vector (A01.02 = 02). The Torque Limit Function limits the
amount of motor torque on all four quadrants of vector control operation:
•
Forward Motoring
•
Reverse Motoring
•
Forward Regenerating
•
Reverse Regenerating
When the torque limits are reached during operation, the programmed acceleration and deceleration
times become second priority.
Brake Answerback
The following timers are used when a multi-function input (H01.01–H01.07) is set for 58, brake
answerback.
Parameter
Code
Name
Function
Range
Initial Value
Access
Level
C07.01
Forward Torque Limit
FORWARD torque limit
000–300%
150
Adv
C07.02
Reverse Torque Limit
REVERSE torque limit
000–300%
150
Adv
C07.03
Forward Regen Torque Limit
Regenerative torque limit at
FORWARD
000–300%
180
Adv
C07.04
Reverse Regen Torque Limit
Regenerative torque limit at
REVERSE
000–300%
180
Adv
C07.05
Torque Limit Gain
Used when H1-01~H1-07 =
14 and MFI is on
0.00–2.55
1.25
Adv
C07.06
Torque Limit Time Constant
Torque Limit Integral Time
Constant
5–10000ms
00200
Adv
C07.07
Torque Limit Select
Torque Limit Select
00–01
00
Adv
00 P Control
01 PI Control
Parameter
Code
Name
Function
Range
Initial Value
Access
Level
C08.04
Rollback Timer
Sets the amount of time for
the brake to release and for
brake feedback to be received
into the Brake Answer Back
Multi-Function input at start
before posting BE4 alarm. It is
also the time period during
which the amount of roll back
is checked.
0.00–2.55 sec
0.30
Adv
C08.11
Brake Set Delay
Sets the amount of time for
the brake to set and for brake
feedback to be removed from
the Brake Answer Back
Multi-Function input at stop
before posting a BE5 Alarm.
0.0–25.5 sec
0.7
Adv
C08.17
Up Speed Limit
Maximum speed in Forward
(Up) direction by BE6.
0.00–150.00
6.00
Adv
Содержание 2001-G+M
Страница 2: ......
Страница 9: ...C h a p t e r 1 Introduction...
Страница 10: ...IMPULSE G Mini Advanced Instruction Manual March 2014 1 2 This page intentionally left blank...
Страница 16: ...IMPULSE G Mini Advanced Instruction Manual March 2014 1 8 This page intentionally left blank...
Страница 17: ...C h a p t e r 2 Installation...
Страница 18: ...IMPULSE G Mini Advanced Instruction Manual March 2014 2 2 This page intentionally left blank...
Страница 25: ...C h a p t e r 3 Wiring...
Страница 26: ...IMPULSE G Mini Advanced Instruction Manual March 2014 3 2 This page intentionally left blank...
Страница 38: ...IMPULSE G Mini Advanced Instruction Manual March 2014 3 14 This page intentionally left blank...
Страница 39: ...C h a p t e r 4 Getting Started...
Страница 40: ...IMPULSE G Mini Advanced Instruction Manual March 2014 4 2 This page intentionally left blank...
Страница 60: ...IMPULSE G Mini Advanced Instruction Manual March 2014 4 22 This page intentionally left blank...
Страница 61: ...C h a p t e r 5 Programming Features...
Страница 62: ...IMPULSE G Mini Advanced Instruction Manual March 2014 5 2 This page intentionally left blank...
Страница 88: ...IMPULSE G Mini Advanced Instruction Manual March 2014 5 28 Figure 5 17 Swift Lift Timing Diagram...
Страница 153: ...Troubleshooting IMPULSE G Mini C h a p t e r 6...
Страница 154: ...IMPULSE G Mini Advanced Instruction Manual March 2014 6 2 This page intentionally left blank...
Страница 165: ...IMPULSE G Mini Advanced Parameter Listing A p p e n d i x A...
Страница 166: ...IMPULSE G Mini Advanced Instruction Manual March 2014 A 2 This page intentionally left blank...
Страница 190: ...IMPULSE G Mini Advanced Instruction Manual March 2014 A 26 This page intentionally left blank...