Symptom
Problem
Solution
Section
Low refrigerant level
Add refrigerant. Contact Dealer.
Clutch coil burned out or
disconnected
Blower motor disconnected or
burned out
Contact Dealer.
Switch contacts in thermostat
burned excessively, or sensing
element defective
Replace thermostat.
Compressor partially or
completely seized
Remove compressor for service or
replacement.
Contact Dealer
Condenser
fi
ns plugged
Clean condenser.
Cleaning Left
Cooling Module,
page 272
Loose or broken compressor
drive belt
Replace drive belt and/ or tighten to
speci
fi
cations.
Tensioning Air
Conditioner (A/C)
Compressor Belts,
page 321
and
Replacing Air
Conditioner (A/C)
Compressor Belts,
page 322
Dirty
fi
lters
Clean fresh air and recirculation
fi
lters.
5.8.1 Servicing
Return Air Filter,
page 271
Broken or disconnected
electrical wire
Check all terminals for loose
connections; check wiring for hidden
breaks.
Broken or disconnected
ground wire
Check ground wire to see if loose,
broken, or disconnected.
—
Expansion valve stuck in open
or closed position
Broken refrigerant line
Leak in system
Compressor shaft seal leaking
Air conditioning not
cooling
Clogged screen in
receiver-drier; plugged hose
or coil
Contact Dealer.
Contact Dealer
214053
372
Revision A
Содержание M1240
Страница 29: ...SAFETY 1 11 Safety Sign Locations Figure 1 31 Safety Sign Locations 214053 17 Revision A ...
Страница 40: ......
Страница 116: ......
Страница 246: ......
Страница 352: ...MAINTENANCE AND SERVICING Figure 5 175 Main Fuse Panel Decal MD 207815 214053 340 Revision A ...
Страница 353: ...MAINTENANCE AND SERVICING Figure 5 176 Relay Module Fuse Panel Decal MD 207816 214053 341 Revision A ...
Страница 355: ...MAINTENANCE AND SERVICING Figure 5 178 Roof Headliner Fuse Decal MD 207819 214053 343 Revision A ...
Страница 370: ......
Страница 388: ......
Страница 487: ......