Adjusting Knife Alarm Pressure – Auger Header
This adjustment requires the header to be in operation.
1. If RUN SCREEN 1 is not already displayed, press soft
key 1 (A) on the Harvest Performance Tracker (HPT)
to display auger RUN SCREEN 1.
Figure 4.257: Header Run Screen 1
2. Press the scroll knob (A) on the Harvest Performance
Tracker (HPT) or the SELECT button (B) on the ground
speed lever (GSL) to display the QuickMenu system.
Figure 4.258: HPT Scroll Knob and GSL
Select Button
3. Scroll to and select the KNIFE ALARM PRESSURE
setting (A).
4. Adjust knife alarm pressure to 0–31,027 kPa (4500 psi)
(alarm range 15,513–31,027 kPa (2250–4500 psi).
NOTE:
Default is 24,821 kPa (3600 psi).
Figure 4.259: Knife Screen
214053
224
Revision A