91
DL8 USERS
MANUAL EM-7691-B Rev.24
8.8.3.2 VERIFICATION WITH TERMINAL SOFTWARE
(1) Connect the DL8 and the PC with the COP-US cable.
COP-US
CFG
(2) Start PC terminal software program, and set communication parameters as shown below.
Baud rate : 38400 bps
Data
: 8 bit
Start bit : 1
Stop bit : 1
Parity
: None
(3) Turn on the DIP SW1 at the front of the DL8.
(4) When FTP transfer is started, communication log can be checked by the terminal software.
While watching the log, confirm the settings until transfer is successfully completed.
(5) After status confirmation is completed, turn off the DIP SW1.
NOTE
• When DIP SW1 on the front of the device is ON, communication with the DLCFG is not available.
After confirming completion of FTP transfer, be sure to turn it OFF.
• Hyper Terminal incorporated in Windows or other free software such as Tera Term can be used as terminal software.