MM102225V1, Rev. B
40
SYSTEM
COMMUNI-
CATIONS
ACTION
MISCELLANEOUS
8.
The photograph to the right shows the
in-rack connection point for T1
communications.
The destination of this connection will
vary by site; however, verify that a
modular style plug wired (T568B) is
used to connect the site communications
interface with the base site T1.
If equipped with ISM Backhaul, the
Orange cable is the 10BaseT connection
to the ISM Backhaul Router.
Note:
Actual cables may be different
colors
.
RECEIVE
ANTENNA
CONNECTION
ACTION
MISCELLANEOUS
9.
The photograph to the right shows the
in-rack connection point for the system
receive antenna. Verify that the jumper
cable to the receive antenna is present
and
disconnect it from the receive input.
Note:
This is only for Tower Top
Amplifier sites.
TTA
CONTROL
CABLE
ACTION
MISCELLANEOUS
10.
Ensure that the 5-conductor Tower Top
Amplifier control cable is connected as
shown in the photo to the right.
Note:
The connector is installed in the
field. To solder the connector to the
cable, refer to APPENDIX A
.
Содержание P5100 Series
Страница 2: ...Installation Manual MM102225V1 Rev B Jul 05 Base Station Tower Site ...
Страница 70: ...MM102225V1 Rev B 69 This page intentionally left blank ...
Страница 72: ...MM102225V1 Rev B 71 This page intentionally left blank ...
Страница 74: ...MM102225V1 Rev B 73 This page intentionally left blank ...
Страница 76: ...MM102225V1 Rev B 75 This page intentionally left blank ...
Страница 82: ...MM102225V1 Rev B 81 PARAMETER VALUE EXPLANATION password cisco login end buck40sas ...
Страница 92: ...MM102225V1 Rev B 91 This page intentionally left blank ...
Страница 94: ...MM102225V1 Rev B 93 This page intentionally left blank ...
Страница 96: ...MM102225V1 Rev B 95 This page intentionally left blank ...
Страница 99: ...MM102225V1 Rev B 98 This page intentionally left blank ...