![Lust MASTERCONTROL MC6000 Series Скачать руководство пользователя страница 156](http://html1.mh-extra.com/html/lust/mastercontrol-mc6000-series/mastercontrol-mc6000-series_instruction-manual_1950408156.webp)
Instruction Manual MC6000
11-7
SIEXT
(continued)
SCTL2
Status Control 2
Control word 2 for setting external outputs
via serial interface
Parameter number:
494
Physical unit:
binary, 8 bit
Value range:
see table below
Factory setting:
00h
Customer setting:
Display level:
3
Editing level:
3
S
MART
C
ARD
area
OPTN2
Bit
Function
0
set/reset output OE00
1
set/reset output OE01
2
set/reset outputOE02
3
set/reset output OE03
SOEXT
Status Word Output Extern
Status word of external output
for monitoring outputs via serial interface
Parameter number:
480
Physical unit
binary, 8 bit
Value range:
see table below
Factory setting:
00h
Customer setting:
Display level:
3
Editing level:
cannot be edited
Bit
Function
0
monitor output OE00
1
monitor output OE01
2
monitor output OE02
3
monitor OE03 output
Bit
Function
0
monitor input IE00
1
monitor input IE01
:
:
:
:
7
monitor input IE07
Note:
The output must be assigned to the serial
interface with the function selector:
FOExx= SIO.
Содержание MASTERCONTROL MC6000 Series
Страница 10: ...MC6000 Instruction Manual 1 2 1 3 Manufacturer s Declaration for Servocontrollers ...
Страница 11: ...MC6000 Instruction Manual 1 3 ...
Страница 12: ...MC6000 Instruction Manual 1 4 1 4 Manufacturer s Declaration for Servomotors ...
Страница 13: ...MC6000 Instruction Manual 1 5 ...
Страница 15: ...MC6000 Instruction Manual 1 7 Copy of Summary ofTest Results as an example for MC6404 and MC6408 ...