Instruction Manual MC6000
10-19
ECLNC
Encoder Line Count
Line count of the encoder
(only for G1, G2, G3)
Parameter number:
331
Physical unit:
-
Value range:
512 - 4096
Factory setting:
2048
Customer setting:
Display level:
4
Editing level:
4
S
MART
C
ARD
area:
DRIVE
ECNPP
Encoder Number of Pole Pairs
Pole pair number of encoder
(only for R1, R2, R8 resolves)
Parameter number:
334
Physical unit:
-
Value range:
see table below
Factory setting:
depending on resolver
Customer setting:
Display level:
4
Editing level:
4
S
MART
C
ARD
area:
DRIVE
Note:
The number of pole pairs of the motor must be equivalent to that of the motor or simply one (
see
table above).
ECOFF
Encoder Offset
Offset of encoder
(correction value for physical installation)
Parameter number:
333
Physical unit:
hexadecimal
Value range:
0000h - FFFFh
Factory setting:
je nach Einbaulage
Customer setting:
Display level:
4
Editing level:
cannot be edited
S
MART
C
ARD
area:
DRIVE
Setting
Pole pair no.
Resolver type
Motor type
1
1
R1
AS, PS
2
2
R2
AS
3
3
R8
PS
4
reserved
AS = asynchronous motor
PS = synchronous motor
10.3.2
Encoder Area (_ENCD)
Changes to parameters in this area only become effective after reinitialization (
see Section 6.7)
_CONF
_ENCD
_OPT2
_OPT1
_MOT
_TCON
_SCON
_PCON
_SIO
_KPAD
_SCTY
_REF
Содержание MASTERCONTROL MC6000 Series
Страница 10: ...MC6000 Instruction Manual 1 2 1 3 Manufacturer s Declaration for Servocontrollers ...
Страница 11: ...MC6000 Instruction Manual 1 3 ...
Страница 12: ...MC6000 Instruction Manual 1 4 1 4 Manufacturer s Declaration for Servomotors ...
Страница 13: ...MC6000 Instruction Manual 1 5 ...
Страница 15: ...MC6000 Instruction Manual 1 7 Copy of Summary ofTest Results as an example for MC6404 and MC6408 ...