Chapter 5 Menu Setup
Alarm Priority: The higher the channel number is, the lower the priority level is. For example,
IN 1 Alarm is higher than IN2 Alarm, so on and so forth. If high priority channel and low
priority channel trigger alarm simultaneously, the preset of the latter will not be called, but if
you have set the alarm output for the latter, its alarm information will be displayed. For
example, when IN1 alarm is on, IN2 alarm almost triggers alarm at the same time and IN2
alarm in ―Out Condition‖ is enabled, the alarm information of IN2 alarm channel is allowed
to output but the preset of it will not be called.
Note
: If the dome is on the menu state on an alarm, any command is negative.
5.3.4
Trace Setup
Enter Main Menu
Dome Function
Trace Setup Menu as shown below:
This function is used to memorize the operation to PTZ, zoom and focus so that repeating
operation progress can be realized by running trace.
Setting Steps:
Step 1: Choose the trace number.
Step 2: Edit the trace. Enter the trace setting menu. Control the dome movement by direction
button and then call preset 1 to save the setting. Each trace can record up to 180s. If the time
exceeds 180s, the system will automatically save the operation data and return to the previous
menu. In addition, 360 commands can be record for each trace at most. If exceeding 360
commands, the system will automatically save the first 360 commands and then exit the
current menu. The recording time is related to the operating frequency. The more frequent the
operation is, the shorter the memory time is.
Step 3: Select ―RUN CUR TRACE…‖ to perform the command.
5.3.5
Day & Night
Enter the Main Menu
Dome Function
Day Night menu as below:
IP-CAMERA User Manual -