![Lindsay FIRLDNET GSM CELLULAR RTU Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/lindsay/firldnet-gsm-cellular-rtu/firldnet-gsm-cellular-rtu_installation-manual_1919636011.webp)
P/N 1389990 Rev B (ECN 32099)
11
Spread Spectrum Installation Guide
Bridge along with a high speed Internet connection. The Bridge does not include or
require a monitor, keyboard or mouse. The Bridge only needs to be plugged in and
powered on. The software on the Bridge starts automatically when it is powered on. If
the Bridge is ever turned off or looses power the software will start up automatically
once someone powers it back on. If the Internet connection for the Bridge is lost the
Bridge will automatically resume operating when the Internet connection is restored.
The Bridge does not need to be backed up since data is not stored on the Bridge. A
UPS (uninterruptible power supply, not included) will allow the Bridge to remain
operational in the event of a power failure
3.4 Base RTU
The Base RTU receives data from the
pivot’s RTUs
then passes that data
to the Bridge. The Base RTU also transmits commands sent to the Bridge
from the Web Portal to the pivot
’s
RTUs. A FieldNET RTU is configured as
a Base by an internal switch. The Base RTU receives its power from the
Bridge. Data and power to the Base RTU are in the same cable.
3.5 Basic Link
The Basic link is used to monitor and control panels that are
not FieldBOSS or FieldVISION. The control panel is wired into
the Basic Link and the Basic Link is connected to a FieldNET
RTU. The Basic Link has (4) 120 VAC inputs and two relay
outputs. One relay is used for a start signal and the other is
used for a stop signal. The Basic Link has field wiring
terminals for the Normally Open contacts of the start relay and
Normally Open and Normally Closed contacts for the Stop
relay.
The Basic Link is shipped assembled to a bracket with a 12
VDC power supply. The 10 Pin connector is pre-wired to monitor and stop most panels.
Instructions are included with the Basic Link for connecting it to BASIC, AIMS Basic,
AIMS Advanced and Valley
’s
Mechanical, Basic, Select and Pro panels. Control kits
are available for each of the above mentioned kits to add remote start capabilities.
The Basic Link monitors the following 120 VAC circuits:
120 VAC Circuits
Monitor
H2O
Wet/Dry
Accessory
On/Off
Forward
Forward/Reverse/Stopped
% Timer
Rate
Содержание FIRLDNET GSM CELLULAR RTU
Страница 1: ...Spread Spectrum Installation Manual PN 13 8999 0 Rev B ECN 32099 GSM CELLULAR RTU SX N3000 SX R3000...
Страница 2: ...P N 1389990 Rev B ECN 32099 2 Spread Spectrum Installation Guide...
Страница 28: ...P N 1389990 Rev B ECN 32099 28 Spread Spectrum Installation Guide 5 0 Wiring Diagrams 5 1 FieldBOSS FieldVISION...
Страница 29: ...P N 1389990 Rev B ECN 32099 29 Spread Spectrum Installation Guide 5 2 FieldBASIC monitor stop...
Страница 30: ...P N 1389990 Rev B ECN 32099 30 Spread Spectrum Installation Guide 5 3 FieldBASIC monitor start stop...
Страница 31: ...P N 1389990 Rev B ECN 32099 31 Spread Spectrum Installation Guide 5 4 AIMS Advanced monitor stop...
Страница 32: ...P N 1389990 Rev B ECN 32099 32 Spread Spectrum Installation Guide 5 5 AIMS Advanced monitor start stop...
Страница 33: ...P N 1389990 Rev B ECN 32099 33 Spread Spectrum Installation Guide 5 6 AIMS Basic monitor stop...
Страница 34: ...P N 1389990 Rev B ECN 32099 34 Spread Spectrum Installation Guide 5 7 AIMS Basic monitor start stop...
Страница 35: ...P N 1389990 Rev B ECN 32099 35 Spread Spectrum Installation Guide 5 8 Valley Mechanical Basic monitor stop...
Страница 37: ...P N 1389990 Rev B ECN 32099 37 Spread Spectrum Installation Guide 5 10 Valley Select monitor stop...
Страница 38: ...P N 1389990 Rev B ECN 32099 38 Spread Spectrum Installation Guide 5 11 Valley Select monitor start stop...
Страница 39: ...P N 1389990 Rev B ECN 32099 39 Spread Spectrum Installation Guide 5 12 Valley CAMS Pro monitor stop...
Страница 40: ...P N 1389990 Rev B ECN 32099 40 Spread Spectrum Installation Guide 5 13 Valley CAMS Pro monitor start stop...
Страница 41: ...P N 1389990 Rev B ECN 32099 41 Spread Spectrum Installation Guide 5 14 Pressure Switch Installation...