Charger fuses *
Two 25 A fuses protect the in-built charger secondary
circuit.
Fuse changing is only permitted once the charger has
been disconnected from the mains voltage and the battery
voltage.
The output fuses are changed by opening the charger (and
dismantling the base plate). Press the fuses home in their
holder.
DANGER
For dismantling the base plate, wait at least 10
minutes after the mains connector has been
disconnected so as to eliminate any risk of
electric shock.
* Option
The operations described below apply to lead-acid batte-
ries with liquid electrolyte.
For “maintenance-free” batteries with gel electrolyte, refer
to the manufacturer’s instructions.
CAUTION
Avoid any contact with the acid. Do not create any
short-circuit. See the recommendations in the
“daily checks” section.
Checking electrolyte level and topping up
with water.
-
This check, and any necessary topping-up, is to be
carried out once a week, after recharging the battery.
-
Turn off the key-switch, open the cover and disconnect the
battery connector.
-
Check the level. It should be up to the base of the filler
plug, just above the top of the separator.
-
Use demineralised water to top up any cells with a low
water level.
-
Replace the filler plugs.
ATTENTION
Use only demineralised water for topping up.
Never add water before charging (risk of
overspill).
Do not overfill the cells.
For more information, refer to the instructions supplied
with the battery.
Checking the electrolyte specific gravity
-
Measuring the specific gravity gives an accurate indica-
tion of the state of charge of each cell in the battery. This
measurement may be carried out before or after charging.
-
Minimum specific gravity, battery 80% discharged: 1.14
-
High specific gravity, battery 100% charged: 1.29 to 1.32
(according to make).
-
We recommend measurement every week or two. Keep
a record of the values measured in the service booklet for
your battery.
Maintenance
Maintenance as required
-
Remove the filler plug for each cell as described above.
-
Using an acid hydrometer, carefully measure the specific
gravity in each cell.
-
Replace the filler plugs when finished.
NOTE:
If there are voltage discrepancies between the various
cells, or if any cells show a particula rly low voltage, contact
your local representative. Any discharge below the threshold
of 1.14 will be extremely detrimental to the lifespan of the
battery.
For more information, refer to the instructions supplied
with the battery.
Fuses
-
Remove the front cover for acces to the fuses.
-
The 7.5 A fuse protects the control circuits.
-
The 160 A fuse protects the power circuit of the traction
motor.
-
The 100 A fuse protects the power circuit of the pump
motor
https://www.besttruckmanuals.com/
Содержание T 16
Страница 2: ...https www besttruckmanuals com...
Страница 3: ...https www besttruckmanuals com...
Страница 7: ...3 6 0 8 0 4 2 5 1 1 0 5 0 4 https www besttruckmanuals com...
Страница 9: ...3 6 0 8 0 4 2 5 1 1 0 5 0 4 Technical specifications Description https www besttruckmanuals com...
Страница 46: ...3 6 0 8 0 4 2 5 1 1 0 5 0 4 Resistance https www besttruckmanuals com...
Страница 48: ...3 6 0 8 0 4 2 5 1 1 0 5 0 4 Pulse control LTM https www besttruckmanuals com...
Страница 50: ...3 6 0 8 0 4 2 5 1 1 0 5 0 4 Pulse control with LBC braking https www besttruckmanuals com...
Страница 52: ...3 6 0 8 0 4 2 5 1 1 0 5 0 4 Pulse control LDC https www besttruckmanuals com...