Daily checks and commissioning checks
Charging the battery with the built-in char-
ger ( from 07/2000 )
Every day the truck is used normally, or every two days in
case of non-intensive use, charge the battery at the end of
the shift.
-
Park the truck near a socket outlet (220 V – 10/16 A).
-
Lower the forks, turn off the key switch, remove the key.
-
Open the battery compartment cover (1) for good ventila-
tion.
-
Remove the plug (2) from its port , pay out the wire and
connect the plug to the mains.
-
The charger starts automatically, the green light (3)
flashes, the red light (4) comes on and then goes off and
the charger fan is switched on.
-
At the end of the normal charge, the green light remains
continuously on, and the fan stops.
-
An equalization charge starts automatically 15 minutes
later; the green light remains on and the fan is switched
on.
-
If the charger remains connected to the mains power
supply, it will restart a charge holding cycle every 48
hours, and the green light flashes.
Commissioning
WARNING:
Do not disconnect the battery connector while
charging (green light flashing).
Problems while charging
If a fault occurs while charging, the red light (4) comes on
and the charger stops.
Proceed as follows to resume a charge cycle after detection
of an anomaly:
-
Disconnect the mains power supply
-
Unplug the battery connector for at least 1 minute
-
Reconnect the battery connector, and then plug the mains
power supply in.
Please call one of our dealers if the problem persists.
Putting the mains power supply cable away
-
Stow the cable in the compartment between the battery
box and the chassis.
-
Push the mains plug (2) on the cable into the red safety
support in the battery compartment.
-
C lo se th e c ov er .
IMPORTANT
The truck will operate only if the plug is replaced correc tly.
Charger electrical specifications
Mains power supply 220 V 50 Hz*Nominal battery voltage
24 V
Maximum output power 720 W Maximum current 30 A
Charging time 12 h (240 Ah)
*Other voltages/frequencies available to suit electrical
mains power supply in different countries
Special case of Gel batteries
Batteries with a gel electrolyte must always be charged
using a special charger.
https://www.besttruckmanuals.com/
Содержание T 16
Страница 2: ...https www besttruckmanuals com...
Страница 3: ...https www besttruckmanuals com...
Страница 7: ...3 6 0 8 0 4 2 5 1 1 0 5 0 4 https www besttruckmanuals com...
Страница 9: ...3 6 0 8 0 4 2 5 1 1 0 5 0 4 Technical specifications Description https www besttruckmanuals com...
Страница 46: ...3 6 0 8 0 4 2 5 1 1 0 5 0 4 Resistance https www besttruckmanuals com...
Страница 48: ...3 6 0 8 0 4 2 5 1 1 0 5 0 4 Pulse control LTM https www besttruckmanuals com...
Страница 50: ...3 6 0 8 0 4 2 5 1 1 0 5 0 4 Pulse control with LBC braking https www besttruckmanuals com...
Страница 52: ...3 6 0 8 0 4 2 5 1 1 0 5 0 4 Pulse control LDC https www besttruckmanuals com...