2.3 Short circuit protection
The charger itself does not have a short-circuit protection function, and a short-
circuit protection device needs to be installed at the upper level for short-circuit
protection. It is recommended that the rated current of the supply circuit short-
circuit protection device matching with the current used by the charger. If it is used
at full load, the rated current should be 40A, otherwise the charger will not work
properly. We recommend using circuit breaker with curve C or curve B .
If you do not know how to choose the appropriate short-circuit protection device,
please contact us.
DANGER!
The supply circuit of the charger must be equipped with a short-circuit
protection device, otherwise the charger cannot be used.
2.4 Lightning protection
The charger meets the overvoltage level III.
2.5 Supported power supply system
Both single-phase and three-phase chargers support the following power supply
systems.
● TN-S
● TN-C-S
● TT
● IT(Only single-phase products are supported. )
For single-phase charger, in a power supply system with a neutral line, the voltage
between the phase line and the neutral line cannot be higher than the rated voltage
requirement (240VAC). In a power supply system without a neutral line, the voltage
between the phase line and the phase line cannot be higher than the constant
voltage requirement (240VAC).
For three-phase charger, in a power supply system with a neutral line, the voltage
between the phase line and the neutral line cannot be higher than the rated voltage
requirement (240VAC).