■The depth of the bolts buried in the concrete is not less than 150mm, and the
exposed length is recommended to be 15 to 30mm (maximum does not exceed
50mm). At the same time, the top of the concrete platform must be flat, otherwise
the strength of the post will be affected after installation, and the post will break in
serious cases. The power cable needs to be pulled out more than 1.3m from the
ground, and the exposed length of the cable can be easily installed (the exposed
length of the cable here is based on the installation surface on the top of the
concrete platform).
■Wait for the concrete platform to fully solidify before installing the post. First put
the post down, pass the reserved cable with a length of about 1.3m through the
bottom of the post, and then pull out the power cable from the outlet in the
middle of the post.