background image

E-series AC Charger 

 

Configuration manual V1.3 

 

1.1

 

Representation of safety instructions 

In this manual, you will find symbols used for warnings. The symbols used have the 
following meanings: 
Read these instructions carefully and examine the equipment to use. 
All the applicable local, regional and national regulations must be followed when you 
install, repair or maintain this equipment.   
Do not operate a damaged product. Refer to the support for more information. 

 

DANGER! 

Indicates a hazardous situation, which will result in death or serious bodily injury if 
the corresponding precautions are not taken. 
 
This  equipment  must  only  be  installed,  repaired  and  maintained  by  qualified 
personnel. 

 

WARNING! 

Indicates a potentially situation, which will result in serious bodily injury or charger 
damaged if the corresponding precautions are not taken. 
 
This  equipment  must  only  be  installed,  repaired  and  maintained  by  qualified 
personnel 
 

 

 

Содержание E-Series

Страница 1: ......

Страница 2: ...upply system 8 2 6 Installation steps 9 3 System overview 19 3 1 WLAN 19 3 2 WLAN Access Point 20 3 2 1 User viewing interface 21 3 2 2 Installer view interface 22 1 WI FI Access Point Setting 25 2 Networking Parameters Setting 26 3 RFID Setting 27 4 System Parameter Setting 28 5 System Time Setting 29 6 Fault Record Report 29 7 Charging Record Report 30 8 System Parameter Report 31 9 Run Data Rep...

Страница 3: ...charger The appearance of the E series charger has the strong future and technical feeling it has a halo atmosphere lamp surround the charger It can connect to TN TT IT Only single phase power supply system to meet lots of application scenarios very suitable for household or charging station E series smart charger can run offline or online When running offline you can query and configure the charg...

Страница 4: ... S TT IT TN S TN C S TT TN S TN C S TT Power supply system 1P N PE or 2P PE 1P N PE or 2P PE 3P N PE 3P N PE Rated voltage 230VAC 230VAC 400VAC 400VAC Voltage range 196 264 VAC 196 264 VAC 380 415VAC 380 415VAC Rated output current 32A 32A 32A 32A Frequency Range 50 Hz 1 60 Hz 1 50 Hz 1 60 Hz 1 50 Hz 1 60 Hz 1 50 Hz 1 60 Hz 1 Ambient temperature 25 50 25 50 25 50 25 50 Storage temperature 40 70 40...

Страница 5: ...r maintain this equipment Do not operate a damaged product Refer to the support for more information DANGER Indicates a hazardous situation which will result in death or serious bodily injury if the corresponding precautions are not taken This equipment must only be installed repaired and maintained by qualified personnel WARNING Indicates a potentially situation which will result in serious bodil...

Страница 6: ...rantee Our charger warranty period is 1 year Within 1 year we will repair it free After 1 year the repair service need for charge You can also extend the warranty period by the different sales policy Only the maintenance work expressly permitted by LINCHR may be performed Any other manipulations to the device will also result in loss of warranty A device with broken warranty seals may no longer be...

Страница 7: ...he warranty seal and void the warranty if the warranty seal is broken this proof can no longer be provided whereby the warranty claim expires 1 4 Notes on this manual The manual is part of the product It should be stored throughout the product s life cycle and read before any user uses the product This manual will be updated as the product is upgraded ...

Страница 8: ... Ground fixed post not include in the product 2 2 Environmental requirements The charger can be used outdoors Pay attention to the operating environment to meet the equipment operation otherwise it will affect the service life of the equipment Operation temperature 25 50 Operation humidity 95 Avoid of the strong vibration and shock place to install the charger Keep away of the explosive dangerous ...

Страница 9: ... the charger must be equipped with a short circuit protection device otherwise the charger cannot be used 2 4 Lightning protection The charger meets the overvoltage level III 2 5 Supported power supply system Both single phase and three phase chargers support the following power supply systems TN S TN C S TT IT Only single phase products are supported For single phase charger in a power supply sys...

Страница 10: ...losed the mounting template to the wall The height from the center of the template to the ground is determined according to your ideal height 1500mm is recommended WARNING The wall should be able to support the weight of the charger The four expansion bolts correspond to the four blind holes just punched into the wall It is recommended to use a tool such as a hammer ...

Страница 11: ...e black front cover of the charger remove the anti theft screw located on the top of the mounted bracket and fix the wall mount bracket on the wall with the expansion screws Hang the charger on the wall mounted bracket and then screw up the anti theft screw ...

Страница 12: ... to cut the cross line of the rubber stopper and pass the cable through the rubber stopper Place the cable through the hole in the bottom of the charger into the wiring position inside the charger and then put the rubber stopper in the hole position at the bottom ...

Страница 13: ... tape for easy handling It should be noted that there is no device for fixing the cable at the position of the cable entry so you must leave enough space for the cable to avoid the cable from being pulled by external forces or you can add a cable fixing device to the cable entry to fix cable DANGER Do not supply power during wiring Be careful of electric shock The wire diameter must be 16mm The te...

Страница 14: ...E series AC Charger Configuration manual V1 3 13 Close the wire cover and screw up the wire cover with 4 screws Close the front cover and the installation is finished ...

Страница 15: ...re provided by the installer due to the different conditions on the construction site These parts are not included in your purchase Pour a concrete platform to fix the post Before the concrete platform is poured M10 bolts and 40mm diameter PVC conduits are pre embedded Among them M10 bolts are used to fix the posts and 40mm diameter PVC conduits are used to pull the power cables to the ground ...

Страница 16: ...nd the post will break in serious cases The power cable needs to be pulled out more than 1 3m from the ground and the exposed length of the cable can be easily installed the exposed length of the cable here is based on the installation surface on the top of the concrete platform Wait for the concrete platform to fully solidify before installing the post First put the post down pass the reserved ca...

Страница 17: ... and use M10 nuts and flat washers to secure the post base to the concrete platform In this way the post is installed At the same time an M6 20 bolt needs to be added to the stainless steel nut at the bottom of the base of the post to provide ground protection for the post ...

Страница 18: ...When preparing to hang the charger you need to first remove the wall mounted metal plate that comes with the charger and then remove the four M6 20 bolts on the post hanging plate Finally align the holes of the two metal plates and install M6 20 bolts ...

Страница 19: ...E series AC Charger Configuration manual V1 3 18 Finally hang the charger on the post and each post can hang up to 2 chargers ...

Страница 20: ...communicates with the server of the charging station The server controls and receives the parameters of the charger E series can only be connected via WLAN If the router is connected to the Internet a connection to an OCPP backend can be made 3 1 WLAN E series connected to the Internet via WLAN E series WLAN has two working modes one is Access Point AP mode and the other is Station STA mode The ch...

Страница 21: ...up the WI FI sign to blue the sign can not be saw at first Connect a mobile phone or a computer to the WLAN access point When the mobile phone or computer is connected to the WLAN access point the WI FI sign will blink in blue When the device is connected to the charger s AP access point it needs to disconnect its own data flow otherwise it is easy to be unable to enter the background of the web i...

Страница 22: ...tatus of the charger and the main configuration parameters This can help you make a simple judgment when something goes wrong with the charger You can also open the mobile browser and enter the following URL in the browser to enter the charger background http 192 168 1 1 You can find how to remove the black cover through 2 6 Installation steps Fig 3 3 The current running status of the charger ...

Страница 23: ...by LINCHR Check_sum_tools needs to be run on a computer and the maintenance staff configured on site need to use the computer for authentication confirmation This web interface is a login page You need to enter the verification code to enter the configuration web page Fig 3 4 The login page First of all you need to enter the secret key displayed on the interface in the schematic diagram 1 of check...

Страница 24: ...al number Configuration item name Description 1 WI FI Access Point Setting In the Wi Fi configuration interface select 1 WI FI Access Point Setting to enter the access point setting configuration group which is used to set the SSID and password settings of the access point in STA mode 2 Networking parameter Setting In the Wi Fi configuration interface select 2 Networking parameter Setting to enter...

Страница 25: ...select 5 System Time Setting to enter the system time setting group This setting group will automatically recognize and read the time of the connected device and set it into the charger 6 Fault Record Report In the Wi Fi configuration directory interface select 6 Fault Record Report to view the fault records of the charger The fault record group is used to display the fault records of the charger ...

Страница 26: ... the strength of the Wi Fi hotspot The lower the value the higher the Wi Fi strength For example in the screenshot above the 57dbm space has the strongest WI FI intensity When the configuration is completed a confirmation interface will pop up After confirming that the connected SSID and password are correct click Confirm to configure successfully When the charger is set to STA mode again it will ...

Страница 27: ...re information about the server used for the OCPP protocol connection including what is shown in the table below Setting item Description OCPP Address The address of the server to be connected which can be an IP address or a domain name the charger will automatically recognize Supports WS and WSS which need to be filled in according to the following format ...

Страница 28: ...n to attach the written card to the RFID card reading area At this time the Read RFID post will show the card number that has been read Click Write Card 1 Write Card 2 or Write Card 3 below to write it to the RFID card number position of BANK1 After the modification of the overall card number is completed click the Confirm button of BANK1 in the RFID card setting interface and the system will outp...

Страница 29: ...r The maximum power of the charger also represents whether the charger power supply is single phase or three phase The optional rated is 7KW or 22KW single phase power is up to 7KW and three phase power is up to 22KW Grid Type Access grid type Optional for IT Only single phase and Other TN S TN C S TT RFID Type RFID card type Optional for CPU card and M1 card Connect Mode Charger connection method...

Страница 30: ...System Time Setting interface This interface can directly read the current time of the device being operated such as the current time of the mobile device and then press the Confirm button to write the current time into the charger system The time cannot be manually modified 6 Fault Record Report Fig 3 12 Fault Record Report interface This page is used to display the current fault and historical f...

Страница 31: ...7 Charging Record Report Fig 3 13 Charging Record Report interface This page is used to display the current charging status and historical charging history of the charger You can check the charging start time end time charging capacity and end reason ...

Страница 32: ... V1 3 31 8 System Parameter Report Fig 3 14 System Parameter Report interface This page mainly displays all the current configuration items of the current charger and is used to check whether the configuration items are configured as required ...

Страница 33: ...E series AC Charger Configuration manual V1 3 32 9 Run Data Report Fig 3 15 Run Data Report interface This page mainly displays the current charger status and key parameters ...

Страница 34: ...se check_sum_tools drag the program to be upgraded to the red box shown in the figure and then click the check button At this time a set of MD5 codes will appear in the checksum box Finally enter this set of MD5 codes into the Upgrade file checksum at the bottom of the web page Click the continue button to enter the file selection page select the program to be upgraded click the upgrade button and...

Страница 35: ...nd we support the browsers in the following list Browser Background configuration Program upgrade IE Support Not support Firefox Support Support Chrome Support Recommend Support Recommend Safari Support Support We recommend using a computer to upgrade WARNING Do not turn off the power during the upgrade ...

Страница 36: ... When the WLAN is in AP mode the display light on the charger will be blue Fig 3 18 The WLAN display light Follow the steps in 3 2 2 WLAN Access Point to set the 1 WI FI Access Point Setting and 2 Networking parameter Setting in the list When the setting is completed you need to press the mode switch button in the black display area of the charger and continuously press it for more than 3s you wil...

Страница 37: ...er sends a request Send response but not execute Change Availability The server sends a request Send response and execute Change Configuration The server sends a request Send response but not all are executed Clear Cache The server sends a request Send response and execute Reserve Now The server sends a request Send response and execute Cancel Reservation The server sends a request Send response a...

Страница 38: ...The charger sends a request Interpret information and execute Start Transaction The charger sends a request Interpret information and execute Stop Transaction The charger sends a request Interpret information and execute Meter Values The charger sends a request Interpret information ...

Страница 39: ...isplay the current status and charging status of the charger Fig 4 1 The Display position Display position Display mode Function Area 1 Digital tube character display It can display information such as voltage current charging capacity and fault code Area 2 Signs display light It can display four states of charger connection plug insertion charging and failure Area 3 Tap card area prompt light Ind...

Страница 40: ... X kWH Charged capacity XXX Min Charged time min Character display in case of electrical fault Character style showing in fault state Meaning of characters ERR OCP Overcurrent fault ERR OVP Overvoltage fault ERR LVP Under voltage fault ERR MET Meter or metering communication fault ERR PE Ground fault ERR CP CP voltage error fault ERR R12 Relay 1 sticking fault ERR R3N Relay 2 sticking fault ERR RO...

Страница 41: ... File error Signs display light Signs Application Function Networking indicator Steady blue the charger is in AP mode Blinking blue the charger is in AP mode and there are devices connected to the charger background Steady green the charger is in STA mode Blinking green The charger is connected to the Internet Solid red the built in networking module of the charging pile is damaged Plug light Soli...

Страница 42: ...onnected to the vehicle the tap card area four corners will light up indicating that the charger can use the RFID card to working Using the RFID card for charging follow these steps 1 Pull the plug off the charger then push the plug all the way into the vehicle inlet For the socket mode of the charger first connect the plug to the charger then connect to the vehicle When the indicator of the card ...

Страница 43: ...ase contact our after sales service team When using OCPP protocol for communication the RFID card used must be a card approved by the server The charger connected to the server will emit two beeps The interval is about 0 5 seconds when performing a card swipe operation The first beep About 1 second represents the charger accepting the card swipe request and the second beep About 1 second represent...

Страница 44: ... maximum actual current depends on the rated cable current carrying capacity of the connection line Differentiated by the PP resistance value in the plug 4 4 Load balance E series chargers can achieve load balance through OCPP The server can control the charger s current through OCPP s Charging Profile During the charging process when the server changes the current of the charger the PWM communica...

Страница 45: ...E series AC Charger Configuration manual V1 3 44 Made in China www xaLINCHR com ...