E-series AC Charger
Configuration manual V1.3
39
card is currently operational.
Around the charger Atmosphere remind light
It used to display the current
charger status
●Character display in normal state of charger
Fig.4-2: The character display
Character style displayed in
normal state
Meaning of characters
HEL LO
Displayed after power on
XXX.0 V
Input voltage value
XX.X A
Charging current value
XX.X Hz
Frequency of input voltage
XX.X kWH
Charged capacity
XXX Min
Charged time(min)
●Character display in case of electrical fault
Character style showing in fault
state
Meaning of characters
ERR OCP
Overcurrent fault
ERR OVP
Overvoltage fault
ERR LVP
Under voltage fault
ERR MET
Meter or metering communication fault
ERR PE
Ground fault
ERR CP
CP voltage error fault
ERR R12
Relay 1 sticking fault
ERR R3N
Relay 2 sticking fault
ERR ROT
Relay over-temperature fault
ERR ELK
Electronic lock abnormal fault
ERR OCT
Plug holder over temperature fault
ERR IRD
Leakage fault
ERR FAN
Fan stall fault(It will not stop charging, it will
reduce the charging current to protect the
Содержание E-Series
Страница 1: ......
Страница 45: ...E series AC Charger Configuration manual V1 3 44 Made in China www xaLINCHR com ...