Instructions for Model A86B Series 

 

Page 1 of 7   

 

 

 

 

 

 

 

 

 

MODEL 

 

A86B 

 

SERIES 

 

 

 

 

48Vdc Switchmode Utility 

Rectifier / Battery Charger 

 

Used with existing LaMarche Power Cage 

ECN/DATE 

 CPN 112819 

 

 

 

 

 

 

 

 

106 BRADROCK DRIVE

 

DES PLAINES, IL. 60018-1967

 

(847) 299-1188

 

FAX: (847)299-3061

 

ISSUE DATE: 

ECN 17682- 12/07 

 

INSTRUCTION DRAWING NUMBER:     

 

 

                                   

P25-

LA86B-1

 

 

Содержание A86B Series

Страница 1: ... SERIES 48Vdc Switchmode Utility Rectifier Battery Charger Used with existing LaMarche Power Cage ECN DATE CPN 112819 106 BRADROCK DRIVE DES PLAINES IL 60018 1967 847 299 1188 FAX 847 299 3061 ISSUE DATE ECN 17682 12 07 INSTRUCTION DRAWING NUMBER P25 LA86B 1 ...

Страница 2: ...ing wash immediately with soap and water If the electrolyte enters the eye immediately flood the eye with running cold water for at least ten 10 minutes and get medical attention immediately 5 Never smoke or allow a spark or flame in vicinity of a battery 6 Be extra cautious DO NOT drop metal onto a battery It might spark or short circuit the battery or cause an explosion 7 Remove personal metal i...

Страница 3: ...age is detected you should 1 File a claim with the carrier within five 5 days 2 Send a copy of the claim to La Marche Mfg Co 3 Call La Marche Mfg For a RETURN MATERIAL AUTHORIZATION NUMBER Failure to properly file a claim for shipping damages or provide a copy of the claim to La Marche Mfg may void warranty service for any physical damages reported for repair NOMENCLATURE PLATES Each piece of La M...

Страница 4: ...vironmental The rectifier shall remain operational when subjected to the following criteria 2 1 1 Temperature Operational 25 degrees C to 50 degrees C Storage 40 degrees C to 50 degrees C 2 1 2 Altitude Operational 0 meters 0 ft to 10000 ft Storage Meters to 10 000 meters 0 ft to 30 000 ft 2 1 3 Humidity Non Condensing Operational 0 RH to 85 RH Storage 0 RH to 95 RH 3 0 Electrical Specifications 3...

Страница 5: ...ent Temperature range 25 degrees C to 55 degrees C 0 015 degrees C 3 14 Series Output Diode All rectifiers are to be equipped with a series diode in the positive output 3 15 Alarm Signals and Lights 3 15 1 AC Green LED Operates when ac input is above 188Vac extinguishes as input voltage declines to 180Vac 3 15 2 DC Volts Green LED Illuminates when the output voltage is above 48Vdc but below overvo...

Страница 6: ...be read between test points COM and V 3 16 5 Output Current Test Points The unit output current can be read between test points COM and I 10A V 4 0 Troubleshooting Be sure all connections to the cage are correct Check polarities Check for loose connections Be sure all units are locked into place Check for correct AC input and DC output voltages There are no user serviceable parts internal to the A...

Страница 7: ...tion installation adjustments and service arrangements Should minor adjustments be required the local La Marche Sales Representative should be contacted to provide this service All sales are final Only standard LaMarche units will be considered for return A 25 restocking fee is charged when return is factory authorized Special units are not returnable In no event shall La Marche Manufacturing Co h...

Отзывы: