AireLink
60 Installation and User Manual Rev. D
System Installation
Page 69
Figure 5-9: Default User Panel status after successful alignment
15.
When using the integrated lens antenna the minimum distance between the antennas in
Standard
distance mode (see RF Link menu on page 74) is 100 meter. If the system is installed
over a shorter distance, please change the distance setting to
Short
or
Very Short
distance to
avoid receiver saturation which occurs around -31 dBm. The table below shows the distance
ranges for
Standard
,
Short
and
Very Short
distance settings.
Antenna Type
Standard Distance
Short Distance
Very Short Distance
Integrated Lens (SX)
>100 meters
100….50 meters
50…25 meters
The Installation is now completed and the radio link
operational!
Содержание AireLink 60
Страница 1: ...LightPointe AireLink 60 Installation and User Manual...
Страница 28: ...AireLink 60 Installation and User Manual Rev D Introduction Page 28...
Страница 40: ...AireLink 60 Installation and User Manual Rev D Surveying the Installation Site Page 40...
Страница 51: ...AireLink 60 Installation and User Manual Rev D Networking Power and Service Connections Page 51...
Страница 56: ...AireLink 60 Installation and User Manual Rev D Recommended Software Pre Configurations Page 56...
Страница 81: ...AireLink 60 Installation and User Manual Rev D System Installation Page 81...
Страница 112: ...AireLink 60 Installation and User Manual Rev D CLI Command Line Interface Page 112...
Страница 116: ...AireLink 60 Installation and User Manual Rev D Bluetooth AireLink Viewer Page 116...
Страница 121: ...AireLink 60 Installation and User Manual Rev D SNMP Page 121...
Страница 125: ...AireLink 60 Installation and User Manual Rev D Troubleshooting and Diagnostics Page 125...
Страница 129: ...AireLink 60 Installation and User Manual Rev D Advanced Troubleshooting Methods Page 129...
Страница 133: ...AireLink 60 Installation and User Manual Rev D Technical Support Page 133...