AireLink
60 Installation and User Manual Rev. D
Introduction
Page 25
1.2.5
Miscellaneous
1.2.5.1
RSSI Alignment Cables
A digital voltmeter is used to measure the RSSI voltage changes of the receive signal level during
alignment. Two cables, one for each AireLink™ 60 radio unit, are provided with the shipment. The
cables are terminated on one side with a 2-pin female connector for attachment to the AireLink™ 60
waterproofed IP67 RSSI voltage connector located at the side of the radio enclosure. At the opposite
side the cable has banana plug connectors for attachment to a digital voltmeter (see Fig. 1-11).
Figure 1-11: RSSI alignment cables
1.2.5.2
Lightning/ Surge Protection
When using the PoE powering/management option and/or the copper data port rather than the fiber
data port option, we strongly recommend using a surge protector to protect networking equipment
attached to the radio to suffer from potential lightning strikes. In case of the PoE/management port, a
10/100 Mbps solution with built in PoE power protection will be sufficient. To protect the 1000 Mbps
copper data port connection, a GbE capable surge protector solution must be used. Figure 1-14 (left)
below shows examples of Ethernet surge protector in an outdoor rated and weather resistant enclosure
made
by
Enable-IT
http://www.ethernetextender.com/ethernet-extension-products/lightning-
The device in the left of Figure 1-12 is an outdoor rated GbE and PoE+ capable Ethernet lightning/surge
protector (LightPointe part number LM-SURGE-1). LightPointe recommend to install a lightning/surge
protector close to the AireLink radio head to prevent damage to the indoor networking equipment that
is connected to the radio head via CAT5/6 copper cable.
In case the direct two wire 48 Vdc powering option is used, we also strongly recommend using a surge
protector to prevent potential lightning strike surges to enter the in-building power plant. The device
on the right in Figure 1-12 is a 48 Vdc surge protector made by Transtector (
Transtector DCOD 48-2.5)
http://www.smithspower.com/brands/transtector/products/dc-surge-protection/1101-1025
Содержание AireLink 60
Страница 1: ...LightPointe AireLink 60 Installation and User Manual...
Страница 28: ...AireLink 60 Installation and User Manual Rev D Introduction Page 28...
Страница 40: ...AireLink 60 Installation and User Manual Rev D Surveying the Installation Site Page 40...
Страница 51: ...AireLink 60 Installation and User Manual Rev D Networking Power and Service Connections Page 51...
Страница 56: ...AireLink 60 Installation and User Manual Rev D Recommended Software Pre Configurations Page 56...
Страница 81: ...AireLink 60 Installation and User Manual Rev D System Installation Page 81...
Страница 112: ...AireLink 60 Installation and User Manual Rev D CLI Command Line Interface Page 112...
Страница 116: ...AireLink 60 Installation and User Manual Rev D Bluetooth AireLink Viewer Page 116...
Страница 121: ...AireLink 60 Installation and User Manual Rev D SNMP Page 121...
Страница 125: ...AireLink 60 Installation and User Manual Rev D Troubleshooting and Diagnostics Page 125...
Страница 129: ...AireLink 60 Installation and User Manual Rev D Advanced Troubleshooting Methods Page 129...
Страница 133: ...AireLink 60 Installation and User Manual Rev D Technical Support Page 133...