L'HOTELLIER
COMPONENT MAINTENANCE MANUAL
12589-( )
PRINTED IN FRANCE
26-20-50
Page 9001
APR 01/11
SPECIAL TOOLS, FIXTURES AND EQUIPMENT AND CONSUMABLE
TASK 26-20-50-940-806-A01
1. General
A.
This section gives the special tools, fixtures, equipment and consumables that are necessary to
keep the fire extinguisher container serviceable
B.
Special tools, fixtures and equipment are given in Table 9001. Refer to figures 9001, 9002, 9003,
9004 and 9005.
NOTE : You can use equivalent alternatives for the items given in the table
Table 9001
Special Tools, Fixtures, and Equipment
DESCRIPTION PART
NUMBER
SPECIFICATION
SOURCE
(CAGE CODE)
Recharge kit
751770
None
Charging Adapter with
lockpin handle
71804 / 751913
Pressure test plug, fill fitting
OUT70065-00
None
Pressure test cap, neck
OUT72371-00
None
Pressure test cap, neck
nipple
OUT72370-00 None
Pressure test plug, pressure
switch fitting
OUT70066-00
Platform scale with pan
0-100 lb display, 0.02
lb increments
(accuracy 0.001 kg)
Commercially available
Holding fixture
None
None
Make locally from fig 3002
O ring
10217-00
O ring
10215-00
Leak standard detector
1000 bubbles
Closure seal
PN=C28
BS
Le joint français
Reprocessing bench “halon”
OUT751770
Recyclage
Or equivalent
Leak detector
BACHARACH H25-IR
Test bench
OUT72044
Pressure switch plier
OUT72287
The document reference is online, please check the correspondence between the online documentation and the printed version.