L'HOTELLIER
COMPONENT MAINTENANCE MANUAL
12589-( )
PRINTED IN FRANCE
26-20-50
Page 7005
APR 01/11
E.
Make sure the pressure switch is correctly aligned. If the alignment is not correct, do steps B thru
D again.
F.
If necessary, use the pressure switch weld-machining-tool (Figure 3005) to make the flange of
the pressure switch and the shims flush with the flange of the pressure-switch-fitting as follows:
(1)
Loosen the set screws and move the two halves of the pressure switch weld-machining-
tool apart.
(2)
Put the two halves of the pressure switch weld-machining-tool around the pressure-switch
and the switch fitting. Tighten the set screws.
(3)
Adjust thumbscrew on the tool until the cutter touches the parts that must be made flush.
(4)
Carefully turn the pressure switch weld-machining-tool until the flanges and shims are
flush.
NOTE :
Do not remove too much material from either of the flanges.
(5)
Loosen the set screws and remove the tool from the fitting.
(6)
Clean the pressure switch fitting weld area on the container with alcohol and clean cloth.
G.
Use a tungsten inert gas (TIG) welder and the straight-fusion-weld procedure. Weld all around
the joint between the pressure-switch flange and the pressure-switch-fitting flange. Make sure
that the depth of the weld is not more than 0,5 mm (0.020 in).
NOTE :
Do not operate the welder at more than 25 amps.
H.
Remove weld discolorations with a stainless steel wire brush
TASK 26-20-50-410-804-A01
7. Recharge
Kit
Set-Up
WARNING :
MAKE SURE THAT ALL COMPONENTS AND FITTINGS ARE CORRECTLY
TORQUED. MAKE SURE THAT THE FILL AREA HAS A GOOD AIR FLOW, AND
FUMES AND PRESSURE ARE BLED TO THE ATMOSPHERE. DO NOT LET THE
EXTINGUISHING AGENT TOUCH YOUR SKIN. IF THE PRESSURE IS
ACCIDENTALLY RELEASED FROM THE CONTAINER, IT IS DANGEROUS TO
PERSONS AND CAN CAUSE DAMAGE TO EQUIPMENT.
WARNING :
MAKE SURE THAT A PROTECTION CAP IS ALWAYS INSTALLED ON THE
CONTAINER NECK. THIS WILL PREVENT THE POSSIBILITY OF DAMAGE TO A
DISC ASSEMBLY AND ACCIDENTAL RELEASE OF THE CONTENTS OF THE
CONTAINER. ACCIDENTAL RELEASE OF THE PRESSURE IN THE CONTAINER IS
DANGEROUS TO PERSONS.
CAUTION
:
MAKE SURE THAT THE CONTAINER IS FULLY DRY BEFORE YOU FILL THE
CONTAINER TO PREVENT CORROSION.
CAUTION
:
MAKE SURE ALL SUPPLY CYLINDER VALVES ARE CLOSED BEFORE YOU SET UP
THE RECHARGE KIT.
A.
Prepare the recharge kit as follows: (refer to figure 7001 for example)