3. Specification
Data
The specified data are given in Table 1.
Table 1
Specified Data
DESCRIPTION OR FONCTION
CHARACTERISTICS
Operating Pressure
595 to 623,5 psig at +68°F (4100 to 4300 kPa (at
+20°C)
Test Pressure
2074 psig (14300 kPa)
Burst Pressure
3118 psig (21500 kPa) min.
Ambient temperature range
-40°F to +212°F (-40°C to +100°C)
Burst range of disc assembly
3074 to 3654 psig at +248°F (21200 to 25200 kPa at
+120°C)
Burst range of fill and safety fitting
1813 to 2031 psig at +239°F to 284°F
(12500 and 14000 kPa at +115°C to 130°C)
Extinguisher agent (CBrF
3
)
2.646 to 2.746 lbs (1.200 to 1.245 kg)
Nitrogen (N
2
) theorical
0.102 lb (0,046 kg)
Capacity 1550
cm
3
(94.6 in
3
)
Permitted weight loss (cumulative)
±
0.002lb/year (1g/year)
Assembly installation position
Discharge outlets down
Weight of charged container less cartridge and
protection caps
5.970 to 6.234 lbs (2.708 to 2.828 kg)
Minimum Wall Thickness, Container Weldment
0.050 in (1,27 mm)
Thread Size, pressure gage Fitting
MJ14x1.5 4H5H
Thread Size, Neck, Discharge
M42x1.5
Thread Size, Fill and safety fitting Flange
M12x1 - 4H5H