Chapter 5 Frame Editor
5-10
CONST : Set data which is constant with invariable features to Constant. Fixed area like command
or station number of frame is applicable for this. CONST data shall be set as classified into HEX. or
ASCII with max.30 byte available.
ARRAY : Variable area which is changeable data whose contents are variable like TX/RX data is
applicable for this. If set to ARRAY, TX/RX data is meant to be changeable based on frame, thus
specified number of data can be transmitted and received by setting the number of data. The size
set in ARRAY size area shall be the same as the actual number of data to be transmitted and
received. The number of data on the basis of ASCII code’s length can be set up to 240 byte with
total length of frame limited to 256 byte.
[Table 5.3] describes setting items of frame body.
[Table 5.3] Setting of data type
Setting item
Data type
Contents
Remark
HEX
z
Used if set figures are transmitted/received as
they are
z
HEX. figures only available.
z
Setting of the even number of data only
available
[Note1]
z
Data of ‘00’ is unavailable.
[Note2]
z
Setting up to 30 byte available
Ver.2.0
Used for
communication
in HEX. figures
CONST
ASCII
z
Used if set figures or ASCII codes in characters
are transmitted/received
z
Character setting available.
z
Setting up to 15 byte available
Used for
communication
in characters
ARRAY
[Note3]
Convert
z
SD area data of PLC program F/B is converted
into ASCII code when transmitted.
z
Data if received is sent to RD area of PLC
program F/B as converted into HEX.
z
HEX. figures only available.
z
Setting up to 120 byte of data available.
Communication
in figures only
available.
ASCII data out
of HEX. range
is regarded as
an error.