Accessories Installation
ENGLISH
Hydro Kit
Installation Manual
25
Main Pump Connection
Water tank temperature sensor Connection
• Select the suitable pump by referring to the flow rate table with water tem-
perature difference between the entrance and the exit.
*It is recommended that the flow rate is 36LPM.
• Use the pump with enough capacity to guarantee the loss of entire water
pressure and to supply the Hydro Kit with water.
• Select a suitable relay for pump capacity when connecting the pump to the
unit.
• Connect the relay to the terminal block 11 and 12 of the control box.
• Connect sensor housing to PCBʻCN-TH4ʼ connector (red).
1
2
L
N
Pump
(main)
Relay
Pump
Water tank
thermistor
Housing
CN-TH4
CAUTION
• Make sure to supply external power with the pump.
CAUTION
• If water tank temperature sensor is not connected, error will occur.
(CH08) Exclude the case of using floor heating.
Содержание ARNH08GK3A2
Страница 49: ......