background image

 

20/07/2022 

CO 00052 

www.uniteck.fr

 

FR

 

 

Unisolar 20.24 W 

 

 
 
 
 

 

 
 
 
 

 

Regulateur de charge solaire PWM 

(avec sortie contrôlée) 

p.2-16 

 

PWM Solar charge controller 

(with controlled output) 

p.17-31 

 

Regulador de carga solar PWM 

(Con salidad controlada) 

p.32-46 

 

Regolatore di carica solare PWM 
(con uscita controllata) 

www.uniteck.fr 

 
 

10.24 / 20.24 / 30.24 

 

UNI

SOLAR

 

EN 

ES 

IT 

Summary of Contents for UNISOLAR 20.24

Page 1: ...harge solaire PWM avec sortie contrôlée p 2 16 PWM Solar charge controller with controlled output p 17 31 Regulador de carga solar PWM Con salidad controlada p 32 46 Regolatore di carica solare PWM con uscita controllata www uniteck fr 10 24 20 24 30 24 UNISOLAR EN ES IT ...

Page 2: ...ie Vert clignotant batterie pleine Vert en charge Rouge batterie profondément déchargée Connexion panneau solaire Voc 50V Connexion batterie 12V ou 24V Connexion sortie contrôlée 12 ou 24V selon batterie connectée Choix batterie AGM batterie scellée sans entretien VRLA Gel batterie à électrolyte gélifiée Liquide batterie à l électrolyte liquide à bouchon Voyant sortie contrôlée On voyant allumé Of...

Page 3: ...aire Unisolar permet ainsi de recharger parfaitement et à 100 toutes les batteries plomb à électrolyte liquide à électrolyte gélifié GEL AGM ou sans entretien Unisolar intègre de plus une sortie 12V 24V contrôlée évitant la décharge profonde de votre batterie et préservant leur durée de vie INSTALLATION FIXATION Unisolar a été conçu pour une utilisation intérieure Il intègre un capteur de températ...

Page 4: ...ent du régulateur prévoyez un espace libre de 5 cm minimum tout autour du produit Cassez les 2 opercules du capot avec une pince Les câbles sortent via les 2 orifices du capot Fermez le capot en réalisant une poussée de bas en haut Cassez l opercule Les câbles passent par la cloison Fermez le capot en réalisant une poussée de bas en haut 5cm 5cm 5cm 5cm ...

Page 5: ...ion Rail Din Fixez directement l Unisolar sur votre cloison à l aide de 4 vis non fournies 83 mm 97 mm 60 mm 18 5 mm Fixez le support mural à l aide de 3 vis non fournies Clipsez l Unisolar sur le support Clipsez l unisolar sur son support Clipsez le support sur le rail puis faites le glisser sur le rail à l endroit voulu 99 5 mm 34 mm 17 mm ...

Page 6: ...rallèle privilégier le câblage en diagonale pour une uniformisation de la charge décharge Ne pas coupler des batteries de capacités différentes d âges différents ou de technologies différentes A capacité égale préférer une batterie de forte capacité à 2 petites branchées en parallèle PANNEAU PHOTOVOLTAÏQUE Veuillez vérifier que la puissance du panneau photovoltaïque ne dépasse pas la puissance nom...

Page 7: ...on le voyant actif clignote Choisissez votre technologie batterie en appuyant sur le bouton Liquid Batterie liquide au plomb ouverte Gel Batterie Gel AGM Batterie au plomb sans entretien AGM Pour valider votre sélection attendre 5 secondes Le voyant redevient fixe Unisolar mémorise votre dernière configuration Raccordez votre panneau photovoltaïque au régulateur de charge et Raccordez votre consom...

Page 8: ...ur le modèle 30 24 soit 450W en 12V ou 900W en 24V Certains consommateurs ont un appel de courant au démarrage plus important que la puissance nominale indiquée Unisolar autorise ces surconsommations ponctuelles dans la limite de 1 5 fois le courant nominal pendant 5 secondes 1 25 fois le courant nominal pendant 60 secondes Vous pouvez néanmoins connecter les consommateurs directement à la batteri...

Page 9: ...tterie déchargée Conseil Si vous n utilisez pas la sortie contrôlée réduisez ou éteignez vos consommateurs Rouge continu batterie profondément déchargée Conseil Si vous n utilisez pas la sortie contrôlée éteignez impérativement vos consommateurs jusqu à ce que le voyant redevienne vert AFFICHAGE SORTIE CONTROLEE 12V 24V SELON BATTERIE Rouge allumé sortie active Rouge clignotant surconsommation ou ...

Page 10: ... NB Cette étape n intervient pas en mode batterie Gel se référer à la partie régulation de la courbe charge selon la technologie batterie En effet si cette étape est réalisée pour ce type de batterie il peut y avoir un risque d explosion Recondition Brassage de la batterie pour éviter tout phénomène de sulfatation et de stratification Uniquement en Liquide Floating 100 La charge de la batterie est...

Page 11: ... de la batterie Cette tension de gazéification diverge selon la typologie des batteries AGM ou GEL En fonction du mode sélectionné Unisolar délivre un niveau de tension parfaitement adapté à la technologie de votre batterie pour une recharge à 100 Régulation selon la température externe Les caractéristiques chimiques de la batterie varient en fonction de la température ambiante Grâce à son capteur...

Page 12: ...l connecté ou en court circuit Vérifiez les branchements polarité et connexion Fonctionnement normal la tension du panneau est inférieure à la tension batterie ou ensoleillement trop faible Le panneau reprendra la charge dès que la tension panneau sera supérieure à a tension batterie Une ou plusieurs cellules de votre panneau sont masquées Vérifiez la propreté de votre panneau solaire et qu aucune...

Page 13: ...Court circuit en sortie Vérifiez les branchements En cas de 1er court circuit le régulateur réalimentera automatiquement les consommateurs sous 10 secondes En cas de 2e court circuit il est nécessaire de réactiver la sortie 12V en pressant le bouton Les consommateurs seront réalimentés sous 3 secondes Les voyants batteries AGM Gel Liquid Clignotent simultanément Protection thermique la température...

Page 14: ... fois par an Tous les travaux doivent être réalisés conformément aux règlements du pays en vigueur en matière d électricité Cet appareil n est pas prévu pour être utilisé par des personnes y compris les enfants dont les capacités physiques sensorielles ou mentales sont réduites ou des personnes dénuées d expérience ou de connaissance sauf si elles ont pu bénéficier par l intermédiaire d une person...

Page 15: ...nsion 12 24V Détection automatique Sélection type batterie Oui Oui Oui Capacité batterie conseillée 10 à 150Ah 10 à 300 Ah 10 à 450 Ah Compensation température Oui Oui Oui Protection surtension panneau Oui Oui Oui SORTIE CONTROLEE 12 24V Intensité de sortie 1 10A 1 20A 1 30A Tension de sortie 12 24V selon batterie Oui Oui Oui Protection sur consommation Oui Oui Oui Protection batterie faible Oui O...

Page 16: ...ce Mail sav uniteck fr Fax 33 0 4 88 04 72 20 GARANTIE La garantie couvre tout défaut ou vice de fabrication pendant 1 an à compter de la date d achat pièces et main d œuvre La garantie ne couvre pas l usure normale des pièces Ex câbles etc les erreurs de tension panneaux batterie incidents dus à un mauvais usage chute démontage ou toute autre avarie due au transport En cas de défauts retournez le...

Page 17: ...harged Command button switch On Off 12V 24V controlled output push 1 second Battery selection push 5 seconds then selection 1 sec Battery selection AGM sealed lead acid battery maintenance free VRLA Gel Gel cell battery Liquid liquid electrolyte battery with plug Solar panel connection Voc 50V Battery connection 12V ou 24V 12 or 24V controlled output connection depending on the connected battery S...

Page 18: ...isolar perfectly recharges any lead acid batteries up to 100 Liquid electrolyte Gel cell GEL AGM maintenance free Moreover Unisolar incorporates a 12 24V controlled output to help avoid deep discharges of your battery and preserving their lifespan INSTALLATION FIXING Unisolar has been designed for an indoor use It incorporates an external temperature sensor which adjusts the load voltage according...

Page 19: ...ion for cooling the solar charge controller leave a 5 cm free space minimum all around the product Break the 2 caps of the cover with pliers Cables go out via the 2 orifices of the cover Close the cover by pushing from upwards 5cm 5cm 5cm 5cm Break the cap of Cables go through the wall Close the cover by pushing from upwards ...

Page 20: ...24 Din Rail mounting Fix the Unisolar directly to The wall using 4 screws not provided 83 mm 97 mm 60 mm 18 5 mm Fix the bracket using 3 screws not provided Clip the Unisolar on its bracket Clip the Unisolar on its bracket Clip the bracket on the rail and drag it to where you want it to be on the rail 99 5 mm 34 mm 17 mm ...

Page 21: ...s In case of parallel connection favour diagonal wiring for a standardization of the charge discharge Do not couple batteries with different capacities different age or different technologies Prefer a high capacity battery to 2 small connected in parallel for equal capacity PHOTOVOLTAIC PANEL Check that the photovoltaic panel s power does not exceed the power rating of the solar charge controller ...

Page 22: ...old the switch for 5 seconds the active light flickers Select your battery s technology by pressing the button Liquid Open lead acid liquid battery Gel Gel battery AGM Lead battery maintenance free AGM To confirm your selection wait for 5 secondes The light stops flickering Unisolar memorises your last setup Connect your photovoltaic panel to the solar charge controller and Connect your consumer t...

Page 23: ...00W 24V Some consumers have a current draw when turning on that can be higher than the indicated rating power Unisolar allows those temporary overconsumptions limited to 1 5 times the nominal current during 5 secondes 1 25 times the nominal current during 60 secondes Nevertheless you can directly connect the consumers to the battery without going through the connection of the Unisolar and thus use...

Page 24: ...ery discharged Tip If you do not use the controlled output reduce or switch off your consumers Steady red Battery deeply discharged Tip If you do not use the controlled output imperatively switch off your consumers until the light becomes green again 12V 24V CONTROLLED OUTPUT DISPLAY DEPENDING ON THE BATTERY Red light on Ouput active Blinking read Overconsumption or short circuit Off Output inacti...

Page 25: ...current decreases battery nearly full NB This stage does not occur with Gel batteries see charge curve regulation depending on the battery technology Indeed if this stage occurs with this type of battery there might be a risk of explosion Recondition Admixture of the battery to avoid any phenomenon of sulfatation and of stratification only liquid battery Floating 100 The battery charge is complete...

Page 26: ...gasification voltage This voltage changes according to the type of the batteries AGM or GEL Depending on the selected mode Unisolar releases a voltage level adapted to the technology of your battery for a recharge up to 100 Regulation by external outside temperature Chimical characteristics of the battery vary depending on the ambient temperature With its external temperature sensor Unisolar adapt...

Page 27: ...ot properly connected or short circuit Check connections polarity and connection Normal functionning The panel voltage is lower than the battery voltage or too low sunshine The panel gets its charge back as soon as the panel voltage is higher than the battery voltage One or several cells of your panel are hidden Check if your panel is clean and make sure none of the cells are hidden Green Flash Bl...

Page 28: ...ections In case of 1st short circuit solar charge controller will automatically resume recharging consumers within 10 seconds In case of 2nd short circuit you need to restart the 12V output by pushing the button Consumers will be recharged within 3 seconds Battery lights AGM Gel Liquid Blinking simultaneously Thermal protection solar charge controller internal temperature exceeds 85 C Solar charge...

Page 29: ...ections at least once a year All tasks must be realised in compliance with the country regulations in force regarding electricity This device is not designed to be used by people including children whose physical sensory or mental abilities are reduced nor by people lacking of experience or knowledge unless they have benefited of supervision or prior instructions concerning the use of the device g...

Page 30: ...R Voltage selection 12 24V Automatic detection Battery type selection Yes Yes Yes Recommended battery capacity 10 to 150Ah 10 to 300 Ah 10 to 450 Ah Temperature Compensation Yes Yes Yes Panel overvoltageprotection Yes Yes Yes 12 24V OUTPUT CONTROLLER Output current 1 10A 1 20A 1 30A Output voltage 12 24V depending on battery Yes Yes Yes Overconsumption protection Yes Yes Yes Low battery protection...

Page 31: ... sav uniteck fr Fax 33 0 4 88 04 72 20 WARRANTY Warranty covers any defect manufacturing defects for 1 year from the date of its purchase parts and labour Warranty does not cover normal wear of parts Ex cables etc panel module battery voltage errors incidents due to inappropriate use fall disassembly or any damages due to transport In case of failure return the product to your distributor by attac...

Page 32: ...rga Rojo batería muy descargada Botón de mando On Off Salida controlada 12V 24V Apretar 1 segunda Elección batería apretar 5 segundas pues elección 1 sec Elección batería AGM batería sellada sin mantenimiento VRLA Gel batería con electrólito gelificado Liquido batería con electrólito líquido con tapón Conexión panel solar Voc 50V Conexión batería 12V ou 24V Conexión salida controlada 12 o 24V segú...

Page 33: ...r permite así recargar perfectamente y al 100 todas las baterías de plomo a electrólito líquido a electrólito GEL AGM o sin mantenimiento Además Unisolar integra una salida 12V 24V controlada evitando así la descarga profunda de su batería y preservando su vida útil INSTALACIÓN FIJACIÓN Unisolar fue concebido para un uso interior Integra un sensor de temperatura externo cual ajusta la tensión de c...

Page 34: ...regulador prevea un espacio libre de 5 cm mínimum alrededor del producto Rompa los 2 opérculos de la tapa con una pinza Los cables salen via lo 2 agujeros de la tapa Cierre la tapa realizando una empujada desde debajo hasta abajo Rompa el opérculo Cierre la tapa realizando una empujada desde debajo hasta abajo 5cm 5cm 5cm 5cm Los cables pasan por el tabique ...

Page 35: ...arril Din Fije directamente el Unisolar sobre su tabique con 4 tornillos no incluyen 83 mm 97 mm 60 mm 18 5 mm Fije el soporte mural con 3 tornillos no provistos Encaje el Unisolar sobre el soporte Encaje el Unisolar sobre su soporte Encaje el soporte sobre el carril pues deslícele sobre el carril hasta el sitio deseado 99 5 mm 34 mm 17 mm ...

Page 36: ...ralelo privilegie el cableado en diagonal para una uniformación de la carga dsecarga No conecte las baterías de differentes capacidades edades o tecnologías A capacidades iguales preferir una batería de larga capacidad contra 2 pequeñas en paralelo PANEL FOTOVOLTÁICO Por favor verifique que la potencia del panel fotovoltáico no sobrepasa la potencia nominal del regulador de carga No conecte un pan...

Page 37: ...bre el botón el indicador activo parpadea Elija su tecnología batería apoyando sobre el botón o Liquid Batería liquida al plomo abierta o Gel Batería GEL o AGM Batería al plomo sin mantenimiento AGM Para validar su elección espere 5 segundas El indicador vuelva fijo Unisolar memoriza su última configuración Conecte su panel fotovoltáico al regulador de carga y Conecte su consumidor al regulador de...

Page 38: ...a los modelos 30 24 es decir 450W en 12V o 900W en 24V Algunos consumidores tienen un pico de corriente al arranque más importante que la potencia nominal indicada Unisolar autoriza estos sobreconsumos puntuales si no sobrepasan 1 5 veces el corriente nominal durante 5 segundas 1 25 veces el corriente nominal durante 60 segundas Sin embargo puede conectar los consumidores directamente con la bater...

Page 39: ...nuo Batería descargada Consejo Si no utiliza la salida controlada reduzca o apague sus consumidores Rojo continuo Batería muy descargada Consejo Si no utiliza la salida controlada apague imperativamente sus consumidores hasta que el indicador vuélvase verde VISUALIZACION DE LA SALIDA CONTROLADA 12V 24V SEGUN LA BATERÍA Rojo encendido salida activa Rojo parpadeante Sobreconsumo o corto circuito Apa...

Page 40: ...te en modo batería Gel referirse a la parte regulación de la curva de carga según la tecnología batería En efecto si esta etapa está realizada para este tipo de batería puede existir un riesgo de explosión Reenvasado Mezcla de la batería para evitas todo fenómeno de sulfatación y de estratificación únicamente para las baterías liquid Floating 100 La carga de la batería está termina El indicador ve...

Page 41: ...rior de la batería Esta tensión de desgasificación diverge según la tipología de los baterías AGM o GEL En función del modo elegido Unisolar provee un nivel de tensión perfectamente adaptado a la tecnología de su batería para una carga al 100 Regulación según la temperatura externa Las características químicas de la batería varían según la temperatura ambiente Gracias a su sensor de temperatura ex...

Page 42: ...o en corto circuito Verifique las conexiones polaridad y conexión Funcionamiento normal la tensión del panel es inferior a la tensión batería o insolación demasiado baja El panel reemprenderá la carga ya que la tensión panel será superior a la tensión batería Una o varias células de su panel están ocultadas Verifique la limpieza de su panel solar y que no otra célula esta ocultada Verde Flash Indi...

Page 43: ...os en 3 segundas Corto circuito en salida Verifique las conexiones En caso de 1º corto circuito el regulador alimentará de nuevo los consumidores en 10 segundas En caso de 2 corto circuito es neesario activar de nuevo la salida 12V apoyando el botón Los consumidores estarán alimentados en 3 segundas Los indicadores AGM Gel Liquid Parpadean simultáneamente Protección térmica la temperatura interna ...

Page 44: ... Todos los trabajos deben estar realizados conforme a los reglamentos en vigor del país en materia de electricidad Este aparato no es concebido para estar usado por personas niños incluidos cuyas capacidades físicas sensoriales o mentales so reducidas o personas desprovista de experiencia o de conocimiento excepto si se beneficiaron por el intermedio de una persona responsable de su seguridad su o...

Page 45: ...GA Elección tensión 12 24V Detección automática Elección tipo batería Sí Sí Sí Capacidad batería aconsejada 10 à 150Ah 10 à 300 Ah 10 à 450 Ah Compensación temperatura Sí Sí Sí Protección sobretensión panel Sí Sí Sí REGULADOR DE SALIDA 12V 24V Intensidad de salida 1 1 1 Tension de salida 12 o 24V dependiendo de la batería Sí Sí Sí Protección sobreconsumo Sí Sí Sí Protección batería baja Sí Sí Sí C...

Page 46: ...2 20 GARANTIA La garantía cubre todo defecto o todo vicio de fabricación durante 1 año a partir de la fecha de compra Piezas y mano de obra La garantía no cubre el desgaste normal de las piezas ej cables etc los errores de tensión de entrada inversiones de polaridad incidente debido a un malo uso caída desmontaje o toda otra avería debida al transporte En caso de avería devuelva el aparato a su di...