Device parameters and interfaces
Leuze electronic
BPS 34
51
TNT 35/7-24V
8.1.7.1 Module 1: Position value
Description:
With this module, the current position value is output.
Notice!
The position value is the position value calculated from the tape value and the settings for
resolution, preset and offset.
Parameter
Hex coding of module 1 "Position value"
The value listed in the table shows the hex coding of the default settings.
Input data
Notice!
A negative number is represented in the input data by a 1 in the most significant bit.
Output data
none
Parameter
Description
Rel.
addr.
Data
type
Value range
Default
Unit
CR to
module
Sign
Output mode for sign.
0
unsign
8
0: Two's complement
1: Sign + magnitude
0
–
–
Parameter length: 1 byte
a
Internal ad
dress
of module 1
Sign
13
00
Input data
Description
Rel.
addr.
Data
type
Value range
Default
Unit
CR to
module
Position
value
Output of the current position.
0
sign
32
-10’000’000 … +10’000’000
(for a resolution in mm)
0
scaled
–
Input data length: 4 byte
b