Device parameters and interfaces
Leuze
electronic
64
BPS 34
Leuze electronic
Input data
Notice!
These input data signal the state of the BPS 34:
• Init
: Base setting during initial startup of the BPS 34
•
Idle
: The BPS 34 is in idle state (scanning beam is off, but motor is running)
• Measure: The BPS 34 is in measurement state (data are output in module 1)
• Standby: The BPS 34 is in waiting state (laser off and motor off).
Output data
Notice!
The standby function can only be activated while in "Measure" state. This function switches
off the motor and laser. It takes approx. 2 sec. to switch the BPS 34 back on (valid measure-
ment values at the interface)
In "Idle" state, the motor continues to run. Only the laser is switched off. It takes approx.
1 sec. to switch the BPS 34 back on (valid measurement values at the interface)
If the start-stop event is to occur at the switching input, the "function" parameter must be
configured with the "start/stop measurement" parameter in module 7 "Switching input".
Input data
Description
Rel.
addr.
Data
type
Value range
Default
Unit
CR to
module
Status of
position
controller
Signals the current state of the
internal position control of the
BPS 34
0
unsign
8
0: Init
1: Idle
2: Measure
4: Standby
0
–
–
Input data length: 1 byte
d
Output
data
Description
Rel.
addr.
Data
type
Value range
Default
Unit
CR to
module
Start
event
Event starts position measure-
ment
0.0
Bit
0 -> 1: Start
0
–
7 g
Stop event
Event stops position measure-
ment
0.1
Bit
0 -> 1: Stop
0
–
–
BPS
standby
Switches the BPS 34 to standby
operation
0.7
Bit
0: BPS active
1: BPS in standby
0
–
–
Output data length: 1 byte
e
f
g