Device parameters and interfaces
Leuze electronic
BPS 34
57
TNT 35/7-24V
8.1.7.6 Module 6: Scaling
Notice!
Underlined in the CR column are the modules which must be activated in addition to the cur-
rent module.
Description
The scaling function is used to convert the tape values to any unit of measurement. To do
this, the tape value is multiplied by the scaling factor.
Parameter
Notice!
When entering offset values in module 5, it must be ensured that the scaling factor is taken
into account.
Affected by this module are:
• Offset value (module 5)
• Static position limit values 1 and 2 (modules 14 and 15)
• Hysteresis of static position limit values 1 and 2 (modules 14 and 15)
• Dynamic position limit values 1 and 2 (modules 16 and 17)
• Hysteresis of dynamic position limit values 1 and 2 (modules 16 and 17)
The static preset or dynamic preset modules (module 3 or module 4) are not affected by the
scaling.
Parameter
Description
Rel.
addr.
Data
type
Value range
Default
Unit
CR to
module
Scaling
factor in
[‰]
Scaling factor used to convert
the position values
0
unsign
16
0 … 65’535
1’000
Per
thou-
sand
1
Parameter length: 2 byte
a