PROFINET interface
Leuze electronic GmbH + Co. KG
AMS 348
i
91
TNT
35/7-2
4V
Input data
None
Output data
None
Error delay
(velocity)
Specifies in the event of an error
whether the velocity immediately
outputs the value of the "Velocity
in the case of failure" parameter
or outputs the last valid velocity
for the duration of the configured
"error delay time".
3.3
Bit
0: OFF
1: ON
1
–
–
Error delay
time
(velocity)
Errors which occur are sup
-
pressed for the configured time.
If no valid velocity value can be
ascertained during the config
-
ured time, the last valid velocity
value is output. If the error per
-
sists after the time elapses, the
value stored in the "Velocity in
the case of failure" parameter is
output.
4…5 unsign
16Bit
200 … 1000
200
ms
–
Parameter length: 6 bytes
g
h