PROFINET interface
98
AMS 348
i
Leuze electronic GmbH + Co. KG
9.9.3.15 Module 15: Dynamic velocity limit value
PROFINET module identifier
Module ID
1015
Submodule ID
1
Description
The dynamic velocity limit value function compares the current velocity with a stored velocity
within the defined range. If the value is above or below the limit value, the dynamic limit value
status in module 16 is set and, if configured, the output is appropriately set. Limit value, hyste
-
resis, range start and range end are transferred with the output data of this module by the
PROFINET master. The transferred values are activated by Bit 0.0, i.e. if this bit is set, the
AMS 348
i
compares the current velocity with the new limit value conditions.
Note!
Further explanations on the Range start and Range end parameters
"Module 11: Static velocity limit value 1"
Parameter
None
Input data
None
Output data
Output data Description
Rel.
addr.
Data
type
Value
Default Unit
CR to
module
Metr. Inch
Limit value
control
Controls internal processing of
the transferred dynamic limit
value parameters.
0.0
Bit
0: Do not process
1: Process
parameter
–
–
–
Switching
type
Condition for the signal change
of the output/status bit
0.1
Bit
0: Value greater than
limit
1: Value less than limit
–
–
–
Direction
selection
Selection of the direction-depen
-
dent or direction-independent
limit value check.
0.2
Bit
0: Direction indepen
-
dent
1: Direction dependent
–
–
–
Velocity limit
value
Limit value is compared to the
current velocity.
1…2 unsign
16 bit
0 … +20000
–
mm/s
(in/
100)
/s
16h
Velocity
hysteresis
Relative shift to prevent signal
bouncing.
3…4 unsign
16 bit
0 … +20000
–
mm/s
(in/
100)
/s
–
a
b
c
d
e