Display and control panel AMS 348i
Leuze electronic GmbH + Co. KG
AMS 348
i
43
TNT
35/7-2
4V
Orange continuous light
Power LED orange
- Configuration via the display
- No data on the host interface
BUS LED
Off
BUS LED off
- No supply voltage (Power)
- No communication possible
- PROFINET communication not initialized or inactive
Flashing green
BUS LED flashes green
- Initialization of the AMS 348
i
, establishing commu
-
nication
Green continuous light
BUS LED green
- Network mode ok
- Connection and communication to Controller (PLC)
established ("data exchange")
Flashing red
BUS LED flashes red
- Bus error, communication error
- Parameterization or configuration failed ("parameter
failure")
- IO error
- No data exchange
Red continuous light
BUS LED red
- Bus error, network error
- No communication (protocol) to controller estab
-
lished (no data exchange)
Flashing orange
BUS LED flashes orange
- PROFINET wave function