PROFINET interface
56
AMS 348
i
Leuze electronic GmbH + Co. KG
9.5
PROFINET – General information on wiring
A Cat. 5 Ethernet cable should be used for wiring.
For the connection technology transition from M12 to RJ45, a "KDS ET M12 / RJ 45 W
-
4P"
adapter is available that lets you connect standard network cables.
If no standard network cables are to be used (e.g. due to lacking IP… degree of protection),
you can use the "KS ET
-
M12
-
4A
-
P7
-
…" ready-made cables on the AMS 348
i
, see
Table 11.4.5 "Accessories - Ready-made cables for PROFINET" on page 114.
The individual AMS 348
i
devices in a linear topology are connected with the
"KSS ET
-
M12
-
4A
-
M12
-
4A
-
P7
-
…" cable, see Table 11.4.5 "Accessories - Ready-made
cables for PROFINET" on page 114.
For unavailable cable lengths, you can configure your cables yourself. For this purpose,
Leuze offers a D-coded M12 round connector for BUS IN and BUS OUT, see Table 11.4.3
"Accessories – M12 connector" on page 112.
9.6
PROFINET – Cable lengths and shielding
Observe the following maximum cable lengths and shielding types:
Table 9.2:
Cable lengths and shielding
Connection
Interface
Max. cable length
Shielding
AMS – host
PROFINET
-
RT
100 m
Absolutely required
Network from
the first AMS to
the last AMS
PROFINET-RT
The maximum segment
length must not exceed
100 m for 100Base-TX
Twisted Pair (min. Cat. 5)
Absolutely required