PROFINET interface
Leuze electronic GmbH + Co. KG
AMS 348
i
73
TNT
35/7-2
4V
Attention!
The laser measurement system does not permanently store parameters changed via the
PROFINET. Following Power OFF/ON, the currently configured parameters are downloaded
from the PROFINET master. If the PROFINET master is no longer available after power OFF/
ON, the default parameters are valid.
Note!
All input and output modules described in this documentation are described from the view
-
point of the control:
Inputs (I) described are inputs of the control.
Outputs (O) described are outputs of the control.
Parameters (P) described are parameters of the GSD file in the control.
9.9.2
Overview of the GSD modules
Module
Module name
Module contents
(P) = Parameter, (O) = Output, (I) = Input
M1
Position value
(I) Position value
(P) Sign
(P) Unit
(P) Resolution
(P) Count direction
(P) Offset
M2
Static preset
(P) Preset value
(O) Preset teach
(O) Reset preset
M3
Dynamic preset
(O) Preset value
(O) Preset teach
(O) Reset preset
M4
I/O 1
(P) Definition whether output or input
(P) Level/edge input/output
(P) Function for output wiring
(P) Function for input wiring
(I) Signal level input/output
(O) Output activated
M5
I/O 2
(P) Definition whether output or input
(P) Level/edge input/output
(P) Function for output wiring
(P) Function for input wiring
(I) Signal level input/output
(O) Output activated
M6
Status and control
(I) Diagnosis and status of AMS 348
i
(O) Laser control ON/OFF
M7
Position limit value 1
(P) Upper and lower position limit value